background image

 

 

 

 

 

 

Modular VTO 

(VTO4202F-P) 

 

Quick Start Guide   

 

V1.0.1

 

 

Summary of Contents for VTO4202F-P

Page 1: ...Modular VTO VTO4202F P Quick Start Guide V1 0 1 ...

Page 2: ...uld result in property damage data loss lower performance or unpredictable result TIPS Provides methods to help you solve a problem or save you time NOTE Provides additional information as the emphasis and supplement to the text Revision History Version Revision Content Release Time V1 0 0 First release July 2019 Privacy Protection Notice As the device user or data controller you might collect per...

Page 3: ... written notice The product updates might cause some differences between the actual product and the manual Please contact the customer service for the latest program and supplementary documentation There still might be deviation in technical data functions and operations description or errors in print If there is any doubt or dispute please refer to our final explanation Upgrade the reader softwar...

Page 4: ...ce do not put on the device anything filled with liquids in order to prevent liquids from flowing into the device Install the device at well ventilated places do not block its ventilation opening Use the device only within rated input and output range Do not dismantle the device arbitrarily Transport use and store the device within allowed humidity and temperature range Power Requirement The produ...

Page 5: ... 1 1 Installing on the Wall 9 3 1 2 Installing in the Wall 11 Horizontal Vertical Mounting 12 3 2 1 Horizontal Mounting 12 3 2 2 Vertical Mounting 13 Cascade Connection 13 4 Configuration 14 Configuration Process 14 Configuring VTO 14 4 2 1 Initialization 14 4 2 2 Configuring VTO Number 15 4 2 3 Configuring Network Parameters 16 4 2 4 Selecting SIP Servers 17 4 2 5 Adding VTO Devices 20 4 2 6 Addi...

Page 6: ...ce video communication system Function Video call Make video calls on the modular VTO with VTH users Group call Call multiple VTH users at one VTO simultaneously Be monitored Videos captured by the VTO can be viewed in real time support maximum 6 channel video stream Emergency call Press the key to call the Center in case of an emergency Unlock Card fingerprint password and remote unlock Alarm Sup...

Page 7: ... Camera Module Camera module front panel Table 2 1 Camera module front panel description No Name Description 1 Microphone Audio input 2 Camera Monitor area in front of the door 3 Speaker Audio output Camera module rear panel ...

Page 8: ...t power supply electric control lock solenoid lock and exit button See Figure 2 3 3 Ethernet Port Connected to network cables 4 Cascade connection port Connect other modules In case of cascade connection of multiple modules modules need cascade connection User ports Indicator Light Module Indicator light module front panel Table 2 3 Indicator light module description No Name Description 1 Call ind...

Page 9: ... panel of audio module is the same as rear panel of camera module Audio module Table 2 5 Audio module description No Name Description 1 Microphone Audio input 2 Speaker Audio output Button Module One button module two button module and five button module are available Their functions are the same although button quantity is different Here five button module is taken as an example See Figure 2 7 an...

Page 10: ...irectory Display user information according to buttons 2 Call button Call the VTH and call the management center you need to do seetings on the web first Five button module rear panel Table 2 7 Button module rear panel description No Name Description 1 Cascade input port Connected to other modules 2 Cascade output port ...

Page 11: ...ttons to select previous or next item 2 Numeric button Enter the password and VTH nombers For example unlock password is 123456 Enter 123456 3 Call button Press the button to start a call to VTH 4 Call management centre Call management centre Card Swiping Module You can swipe card near the icon shown in Figure 2 10 Rear panel of card swiping module is the same as rear panel of button module Card s...

Page 12: ...ar panels of fingerprint module and button module have different port positions but port functions are the same Fingerprint module Display Module Display module can be used for displaying user information Rear panels of display module and button module have different port positions but port functions are the same ...

Page 13: ...module Blank Module Blank module can be used for more attractive appearance when there is extra space Rear panels of blank module and button module have different port positions but port functions are the same Blank module ...

Page 14: ...o work normally Before installing surface mounting box and flush mounting box cables in the wall shall go through the bracket or mounting box Installing on in the Wall 3 1 1 Installing on the Wall Drill holes according to hole positions of the mounting box and put expansion pipe in place Fix the mounting box onto the wall with ST4 25 screws Fix the rear panel on the mounting box with M2 8 screws C...

Page 15: ...Installation 10 Apply silicone sealant to gaps Installing on the wall ...

Page 16: ...nto the wall with ST4 25 screws ensure that box edge clings to the wall Fix the rear panel on the mounting box with M2 8 screws Connect cables Please refer to 2 Structure Fix every module on the rear panel with M3 8 screws Apply glue to gaps among the rear panel mounting box and wall Write room number or the username on the visiting card and insert it into user directory Apply silicone sealant to ...

Page 17: ... Horizontal mounting 2 When the VTO is horizontally mounted make sure that the tamper switch on the rear panel marked with 1 in Figure 3 4 is retracted so that once the VTO is dismantled tamper switch will be released and then alarms will be triggered The alarm will keep ringing for 15 seconds ...

Page 18: ...e rear panel marked with 1 in Figure 3 5 is retracted so that once the VTO is dismantled tamper switch will be released and then alarms will be triggered The alarm will keep ringing for 15 seconds Cascade Connection To make modules work collaboratively cascade connection is needed See a cascade connection example in Figure 3 7 Cascade connection ...

Page 19: ...e VTO network parameters See 4 2 3 Configuring Network Parameters 4 Configure SIP Server See 4 2 4 Selecting SIP Servers 5 Add VTO devices to the SIP server See 4 2 5 Adding VTO Devices 6 Add room number to the SIP server See 4 2 6 Adding Room Number Configure VTH See the VTH users manual Verify Configuration See 4 3 Verifying Configuration Configuring VTO Connect the VTO to your PC with network c...

Page 20: ...is recommended to finish this setting Click Next The initialization succeeded Click OK The Login interface is displayed See Figure 4 2 Login 4 2 2 Configuring VTO Number The VTO number can be used to differentiate each VTO and it is normally configured according to unit or building number You can change the number of a VTO when it is not working as SIP server The VTO number can contain 5 numbers a...

Page 21: ... interface Select Local Setting Basic The device properties are displayed See Figure 4 4 Device properties In the VTO No input box enter the VTO number you planned for this VTO and then click Confirm to save 4 2 3 Configuring Network Parameters Select Network Setting Basic TCP IP interface is displayed See Figure 4 5 ...

Page 22: ...ist It applies to a scenario where there is only one building When the platform Express DSS works as SIP server select Express DSS from the Server Type drop down list It applies to a scenario where there are multiple buildings or multiple units If the VTO you are operating is the SIP server Building No and Unit No will not be displayed on the Device Properties interface in Local Setting Basic If y...

Page 23: ...tings 3 Restart the device manually or wait for auto reboot to make the settings effective Log in to the web interface again Select Network Setting SIP Server The SIP Server interface is displayed See Figure 4 7 SIP server 1 Select a SIP server VTO as SIP server Select Enable behind SIP Server Select VTO from the Server Type drop down list Configure parameters see Table 4 1 for details Click Save ...

Page 24: ...TS through VTO Port It is 5060 by default when other VTOs work as SIP server It is 5080 by default when the platform works as SIP server Username Password Use default value SIP Domain It shall be VDP when another VTO works as SIP server It can be null or keep default value when the platform works as SIP server Login Username Password Username and password to log in to SIP server Alternate IP Addr ...

Page 25: ...ng and Support Unit first 4 2 5 Adding VTO Devices You can add VTO devices to the SIP server and all the VTO devices connected to the same SIP server can make video call between each other This section applies to the condition in which a VTO device works as SIP server and if you are using other servers as SIP server see the corresponding manual for the detailed configuration Log in to the web inte...

Page 26: ...rface of the target VTO Password Click Save 4 2 6 Adding Room Number You can add the planned room number to the SIP server and then configure the room number on VTH devices to connect them to the network This section applies to the condition in which a VTO device works as SIP server and if you use other servers as SIP server see the corresponding manual for the detailed configuration The room numb...

Page 27: ...ing single room number 1 Click Add See Figure 4 11 The Add interface is displayed See Figure 4 12 Add single room number 2 Configure room information See Table 4 3 Table 4 3 Room information Parameter Description First Name Enter the information you need to differentiate each room Last Name ...

Page 28: ...oom Amount in One Layer First Floor Number and Second Floor Number according to the actual condition 2 Click the Add at the bottom See Figure 4 13 Add in batch All the added room numbers are displayed Click Refresh to view the latest status and click Clear to delete all the room numbers 4 2 7 Configuring Module Camera module is designed by default All other modules need to be added in facade layou...

Page 29: ...ion position of the device on web interface is from top to bottom and from left to right Support adding multiple modules at the same time and saving the configurations Click Confirm and then restart the browser to make the configurations take effective 4 2 7 2 Setting Modules You need to set call keys for button module and camera module respectively Select Local Setting Basic Faç ade Layout The Fa...

Page 30: ...Configuration 25 Set modules Click The Room List interface is displayed See Figure 4 16 The room no displayed on the interface corresponds to the added VTH 888888 is the Centre Call No Room list ...

Page 31: ... information See Figure 4 17 Room No information Click Confirm and then restart the browser to make the configurations take effective save the settings Verifying Configuration 4 3 1 Calling VTH from VTO Dial room number on the VTO Press The VTO is calling the VTH See Figure 4 18 ...

Page 32: ...TH to answer the call 4 3 2 Doing Monitor from VTH On the main interface of the VTH select Monitor Door The Door interface is displayed See Figure 4 19 Door Select the VTO you need to do monitor The monitor screen is displayed See Figure 4 20 ...

Page 33: ...Configuration 28 Monitor screen ...

Page 34: ... enable the auto check for updates function to obtain timely information of firmware updates released by the manufacturer We suggest that you download and use the latest version of client software Nice to have recommendations to improve your equipment network security 1 Physical Protection We suggest that you perform physical protection to equipment especially storage devices For example place the...

Page 35: ...ollowing services SNMP Choose SNMP v3 and set up strong encryption passwords and authentication passwords SMTP Choose TLS to access mailbox server FTP Choose SFTP and set up strong passwords AP hotspot Choose WPA2 PSK encryption mode and set up strong passwords 11 Audio and Video Encrypted Transmission If your audio and video data contents are very important or sensitive we recommend that you use ...

Page 36: ...ds If there are no communication requirements between two sub networks it is suggested to use VLAN network GAP and other technologies to partition the network so as to achieve the network isolation effect Establish the 802 1x access authentication system to reduce the risk of unauthorized access to private networks ...

Reviews: