10
Hisselektronik
www.safeline.se
Dial tone programming
CODE DATA
NOTE
Alarm codes
P100 ID code
*01*
- - - - - - - - #
P100 always 8 digits
CPC ID code
*02*
- - - - - - #
CPC 6-8 digits
Q23 ID code
*03*
- - - - - - - - - - - - #
Q23 always 12 digits
Phone number:
1st Phone no.:
*11*
- - - - - - - - - #
Phone no. To alarm receiver 0-16 digits.
2nd Phone no.:
*12*
- - - - - - - - - #
Phone no. To alarm receiver 0-16 digits.
3rd Phone no.:
*13*
- - - - - - - - - #
Phone no. To alarm receiver 0-16 digits.
4th Phone no.:
*14*
- - - - - - - - - #
Phone no. To alarm receiver 0-16 digits.
Alarm type:
Alarm type
1
st
no.:
*21*
- #
Change alarm type 1-4
th
number:
Alarm type
2
nd
no.:
*22*
- #
0=P100, 1=VOICE, 2=Q23, 3=CPC
Alarm type
3
rd
no.:
*23*
- #
Alarm type
4
th
no.:
*24*
- #
Alarm type
LMS
no.:
*30*
- #
LMS alarm type only CPC/P100
Test alarm/battery alarm:
LMS
Phone no..
*16*
- - - - - - - - - #
LMS phone number.
To alarm receiver / SLCC
Test alarm
*17*
- - - - - - - - - #
Phone number.
To test alarm receiver / SLCC
Days between tests
*27*
- - #
Days between tests.
00-99
days.
Test alarm protocol.
*31*
- #
Protocol test alarm 0 = P100 (SLCC),
3 = CPC
Alarm character
:
Alarm character 1
st
no.:
*41*
- - #
Alarm character. Only when CPC is used
Alarm character 2
nd
no.:
*42*
- - #
as alarm protocol normally 10 or 27.
Alarm character 3
rd
no.:
*43*
- - #
Check with your alarm central!
Alarm character 4
th
no.:
*44*
- - #
Alarm character LMS
*45*
- - #
LMS (Battery alarm) Normally 17
Alarm character Test alarm
*46*
- - #
Test alarm= Normally 26
Number of ring signals.
*72*
- - #
Ring signals before re-dial. (02-50)
Hot Line
*75*
- #
0 = Standard phone line (standard)
1 = Hot line
Automatic answering
*81*
- - #
Set to 00-16 00=Don’t answer.
(standard = 02)
Unit number
.
*82*
- #
0 (standard) - 9
Dial tone detect
*83*
- #
0=Off 1=On (standard)
Set to 0 if SafeLine is having problems detecting
the dial tone.
Receipt to SLCC
*84*
- #
0 = Off (don’t send receipt), 1 = On (send receipt)
Break on new alarm
*86*
- #
0 = Off 1 = On (standard)
Password
*91*
- - - - #
Change password (standard=0000)
Simulate an alarm event
*94*
-
#
Simulates an alarm event.
Note! LMS no. *16* must be programmed.
1 = Emergency alarm.
2 = Test alarm.
5 = Receipt on voice call.
Restore to default:
*99*
1 #
Restores unit to factory default.
End programming:
End programming.
*00#
*00#
End programming.