Airfield Lighting
Safegate Group
Manual
Date: October 2016
Ref: SL-RE-E_SL-RT-E_SL-RN-E_SL-RTN-E_SL-SB-E
Version: 1.4
Page 29 of 42
Connect a PC to the SCM unit
Using the cable supplied (RS-232), connect the shorter cable end with LOAD/RESET (591836) to
the PC and the longer cable end to the LPC.
Note: For more information, see the marking on the LOAD/RESET box.
FIGURE 35
– CONNECT PC TO SCM
Connect the LPC to a SafeLED IQ product
FIGURE 36
– CONNECT LPC TO LIGHT
1. Using the cable supplied (594115), connect to
Output 1
or
Output 2
to a SafeLED IQ product.
Note: The Short Circuit Plug should be connected to the output NOT in use, either Output 1 or
Output 2. The two outputs are connected in series to give equal functionality.
2. Make sure the
Remote
button on the LPC is NOT pressed before you start programming.
3. Turn on the
Power
button.
2.
3.