SC
TFPS
“M”
: Monitoring
“I”
:
indoor housing
“O”
:outdoor housing
“E”
:Europe standard 230V +/- 15% 50Hz
“U”
:USA standard 120V +/- 15% 60Hz
“2200”
: 2200 VA (rms)
“1800”
: 1800 VA (rms)
“1300”
: 1300 VA (rms)
“1080”
: 1080 VA (rms)
“ 300
” : 300 VA (rms)
“D” :
Dual output port.
“S” :
Single output port.
“M” :
Mini P.S.
“60”
: 60V CATV voltage standard.
“90”
: 87V CATV voltage standard.
Safecom T-former P.S ordering information
Model
Output
Port
Output
Voltage
Output
Current [A]
Input
Voltage[V]
Frequency
[Hz]
Housing
Monitoring
SC S TFPS 1080 60UI
Single
66,72
15
110,120
45 ÷ 65
Indoor
-
SC S TFPS 1080 60UO
Single
66,72
15
110,120
45 ÷ 65
Outdoor
-
SC D TFPS 1800 60UI
Dual
66,72
25
110,120
45 ÷ 65
indoor
-
SC D TFPS 1800 60UO
Dual
66,72
25
110,120
45 ÷ 65
outdoor
-
SC S TFPS 1300 90UI
Single
60,75,87
15
110,120
45 ÷ 65
Indoor
-
SC STFPS 1300 90UO
Single
60,75,87
15
110,120
45 ÷ 65
Outdoor
-
SC D TFPS 2200 90UI
Dual
60,75,87
25
110,120
45 ÷ 65
indoor
-
SC D TFPS 2200 90UO
Dual
60,75,87
25
110,120
45 ÷ 65
outdoor
-
SC D TFPS 2200 90UOM
Dual
60,75,87
25
110,120
45 ÷ 65
outdoor
SC S TFPS 1080 60EI
Single
66,72
15
220,230,240
45 ÷ 65
Indoor
-
SC S TFPS 1080 60EO
Single
66,72
15
220,230,240
45 ÷ 65
Outdoor
-
SC D TFPS 1800 60EI
Dual
66,72
25
220,230,240
45 ÷ 65
indoor
-
SC D TFPS 1800 60EO
Dual
66,72
25
220,230,240
45 ÷ 65
outdoor
-
SC S TFPS 1300 90EI
Single
60,75,87
15
220,230,240
45 ÷ 65
Indoor
-
SC STFPS 1300 90EO
Single
60,75,87
15
220,230,240
45 ÷ 65
Outdoor
-
SC D TFPS 2200 90EI
Dual
60,75,87
25
220,230,240
45 ÷ 65
indoor
-
SC D TFPS 2200 90EO
Dual
60,75,87
25
220,230,240
45 ÷ 65
outdoor
-
SC D TFPS 2200 90EOM
Dual
60,75,87
25
220,230,240
45 ÷ 65
outdoor
13