SAFE-AID TS350 WIRED WIND SPEED METER MANUAL - VERSION 1
Page 8
Figure 3
Utilisation
:
Utilisation is the actual wind speed utilised against the wind speed limits. This is
displayed graphically by the bar, proceeding from green (less than
Intermediate Limit
), then
amber (greater than or equal to
Intermediate Limit
but less than
Upper Limit
) and finally
red (greater than or equal to
Upper Limit
) increasing incrementally as a percentage.
If the wind speed is equal to or greater than the Windspeed Intermediate Limit (
Figure 3
) the
following will happen:
The percentage utilisation bar graph will turn yellow
Intermediate Windspeed
will be displayed below the Limit block
The display buzzer will sound intermittently
Top robot type indication light on the top of the screen will change to yellow
The buzzer symbol will be displayed after five seconds
If the wind speed is equal to or greater than the Windspeed Upper Limit (
Figure 4
) the
following will happen:
The percentage utilisation bar graph will turn red
100% Windspeed
will be displayed below the Limit block
The display buzzer will sound permanently until an intermediate condition or lower is
reached
Top robot type indication light on the top of the screen will change to red
The buzzer symbol will be displayed after five seconds
Figure 4 Figure 5