4.2.9
Seam cycle parameters description
Electrodes:
Range value:
from 1 to 4
Default Value:
1
It selects, when activated, the pair of electrodes in the running program, on which to
perform the life management, this parameter is also a reference for management of the
alarm electrodes end of life and for the electrode life reset.
Current:
Range
value:
NO;
YES
Default
value:
NO
If set to NO, the CS-I will perform the welding program meeting all the times set but will not
provide current, set to YES, will provide current flow where required.
Working mode:
Range
value:
D
‰
; V
‰
; IK.
Default value: :
D‰
It sets the mode in which the CS-I / P will supply the power to transformer, duty-‰ (fixed)
"D‰" ‰ duty-compensated voltage Bus "V‰" or constant current "IK"
Limits Check:
Range
value:
NO;
YES
Default value: :
NO
Enables or disables the monitoring of maximum and minimum current limits.
Pressure 0:
Range value:
da 0 a 99%
Default
value
: 0
Sets the output driving the proportional valve during squeeze time and delay weld time
Squeeze SV:
Range value:
from NO,EV1 to EV4
Default
value:
NO
It sets the output number to use at Squeeze start.
Squeeze:
Range value:
in cycles from 0.0 to 199 step 1
In milliseconds from 0 to 3990 step 10ms
Cycles Default value:
0
Default value in ms:
0
It sets the squeeze time.