Pulses 2:
Range value:
from 1 to 10
Default
Value:
1
Set the number of repetitions of welding 2.
Cool time weld 1-2
Range value:
in cycles from 0.5 to 99.0 step 0.5
in milliseconds from 10 to 1980 step 1
Cycles Default Value:
0.5
Milliseconds Default Value:
10
It sets the pause time before repeating cycles of welding 1 and 2, it occurs when the
number of Pulses for weld 1-2 if it is greater than 1.
Pulses weld.1-2
Range value:
from 1 to 10
Default
Value:
1
It sets the number of repetitions for welding 1 and 2.
Slope-Dw:
Range value:
from 0 a 10 step 1
in milliseconds from 0 to 200 step 1
Cycles Default Value:
0
Milliseconds Default Value:
0
It sets the descent time of the last current supplied during the welding.
Cool time 3:
Range value:
in cycles from 0.5 to 99.0 step 0.5
in milliseconds from 10 to 1980 step 10
Cycles Default Value:
0.5
Milliseconds Default Value:
10
It sets the cold time 3 before the post weld.
Temper Time:
Range value:
in cycles from 0 to 999 step 1
in milliseconds from 0 to 19980 step 10
Cycles Default Value:
0
Milliseconds Default Value:
0
It sets the temper time (post weld).
Temper current:
Range
value:
When
in
D
‰
e V
‰
= from 50 to 999 (150A-300A)
from 100 to 999 (450A-600A)
When in IK, EK, AD = from 0.25 to Imax (150A-300A)
from
1.0
to
Imax
(450A-600A)
When in PK = from 0.2 to 600.0KW