CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
30 of 109
Pressure 4:
Range value:
from 0 to 99%
Default
Value:
0
It sets the percentage of voltage if the analogical output for the proportional valve. During
the weld time, if zero does the previously set value does not change.
Cool time 0:
Range value:
in cycles from 0.5 to 99.0 step 0.5
in milliseconds from 10 to 1980 step 10
Cycles Default Value:
0.5
Milliseconds Default Value:
10
IT Sets the Cool time 0.
Slope-Up:
Range value:
in cycles from 0 to 10 step 1
In milliseconds from 0 to 200 step 1
Cycles Default Value:
0
Milliseconds Default Value:
0
It sets the rise time of the welding current.
NB The parameter value is automatically limited or reset to the value of the welding time 1,
if greater than welding time 1
Decr. Res.
Thres.:
Range value:
from 0.1 to 50.0 step 0.1
Default
Value:
0.1
It sets the percentage of decrease in the resistance of the welding core starting from the
peak value detected in adaptive mode "AD".
Weld time 1:
Range value:
in cycles from 0.5 to 99.0 step 0.5
In milliseconds from 1 to 1980 step 1
Cycles Default Value:
0.5
Milliseconds Default Value:
1
It sets the welding time 1.
Weld current 1:
Range
value:
When
in
D
‰
e V
‰
= from 50 to 999 (151A-301A)
from 100 to 999 (451A-601A
When in IK or AD = from 0.25 to Imax (151A-301A)
from 1.0 to Imax (451A-601A)
When in PK = from 0.20 to 600.0KW
When in EK = da 10 a 60000J
Default Value D‰ e V‰:
50/100
Default Value IK , AD:
0.25/1.0
Default Value PK:
0.20
Default Value EK:
10
It sets the current or power during welding time 1.