INTEGRA-W/INTEGRA-WS User Manual WEB GUI
SAF Tehnika JSC
33
Modify mode
1)
Clear alarm log
– deletes all alarm log entries;
2)
Toggle period selection
– opens period selection controls;
3)
Load the latest data
– refreshes alarm log and shows last 20 log entries;
4)
List of alarm log entries – entry number, date and time, source node, status and
event name. Clicking on “Cfg # accepted from <>” will redirect to Configuration file
page and highlight changes made.
5)
Navigation controls. “<<” navigates to start of alarm log, while “>>” – to the end;
“Previous 20” navigates to previous alarm log page showing 20 previous alarm log
entries, while “Next 20” – to next alarm log page showing 20 next alarm log entries
(if available).
6)
Shows number of currently viewed alarm log page. In Web GUI only last 20 pages
(400 entries) are shown. Download alarm log to view full list. You can enter specific
page number to navigate to required page.
7)
Filter
– press to filter alarms from certain source node (e.g. Radio);
8)
Alarm event log file
– press on the link to download full alarm log text file.
CLI commands (
log event show last
<#_of_entries>
Use to show certain number of last alarm log entries.
log event show time
<time>
Use to show entries from a certain time point. Following
formats are supported: YYYY-MM-DD/hh:mm:ss; MM-
DD/hh:mm:ss; MM-DD/hh:mm; hh:mm:ss; hh:mm
log event show sensor
<sensor> <last|time>
<#_of_entries|time>
Use to show entries for a specific sensor. Regarding
subcommands “last” and “time” refer to commands above.
log event show module
<modem|ns|psu|radio|system>
<last|time>
<#_of_entries|time>
Use to show entries for a specific module. Regarding
subcommands “last” and “time” refer to commands above.