Interconnection scheme with CFIP Lumina (electrical):
Front panel has 3 indication LEDS. LED3 indicates position of DIP switch S1 and its color
indication can be ignored in Forced mode (DIP switch S4 in DOWN position).
Load detected and voltage fed at the
output of PoE injector (POWER GOOD)
No load at the output of PoE injector
(OPEN)
PoE controller detected and voltage fed
at the output of PoE injector (POWER
ON)
Short at the output of PoE injector
(SHORT)
Classified PoE mode (PoE CLASSIFIED)
(if S4 is UP; see table below).
Unclassified PoE mode (PoE MANUAL)
(if S4 is UP; see table below).
Back panel has 4 switches in order to operate PoE injector in different modes.
Appropriate I
max
selection while unclassified PoE mode is enabled (S1 UP, S4 UP) will provide
most effective surge protection for the radio. In case of exceeding set I
max
upper LEDs
(LED1&LED2) will blink in green color.
Connecting device in Unclassified or Forced modes will introduce approx. 5 second delay of
LED indication.
In case classified PoE mode is enabled (S1 position DOWN, S4 position UP) I
max
mode (PD
class) is negotiated automatically with the FODU.
Position of DIP switches should be changed only while PoE injector is turned off.