![Saf-Fro PRESTOJET 30K Operator'S Manual Download Page 15](http://html.mh-extra.com/html/saf-fro/prestojet-30k/prestojet-30k_operators-manual_796166015.webp)
English 13 English
Preparing the equipment
PRESTOJET 30K
enables the cutting and grid process.
WARNING
When preparing to work, make sure you have all materials
needed to complete the work and have taken all safety
precautions.
Procedure of begin of process:
Turn the machine off.
Connect the torch from the kit into the connector [5].
Connect the work lead into the connector [3].
Connect the other part of work lead to the material to
be cut.
Turn the machine on [8]. Check the LED [9] lights
green and LED [11] is not lights red.
Select a compressed air source [15].
Select the airflow by switch [16] to “SET”. Unlock the
control [14] – pull control towards you and by turning
to the right or left to set proper pressure.
WARNING
The recommended value pressure for high-quality cut is
5,5 bar for external mains.
WARNING
“Safety” function in torch – The button cover that prevents
accidental ignition of the torch.
WARNING
The User cannot start the cutting process, if the starts the
equipment with the button in the handle is pressed.
Set the cutting current [17].
The equipment is now ready.
WARNING
To start the cutting process just press the torch button,
making sure you are not aiming the torch air blow towards
people or foreign objects.
By applying the principle of occupational health and
safety, gouging can be begun.
PRESTOJET 45
enables be cut, grid and gouging.
PRESTOJET 45
does not include the accessories for
gauging, but the one can be purchased separately (see
"Accessories" chapter).
WARNING
When preparing to work, make sure you have all materials
needed to complete the work and have taken all safety
precautions.
Procedure of begin process:
Turn the machine off.
Connect the torch from the kit into the socket [5].
Connect the work lead into the socket [3].
Connect the other part of work lead to the material.
Turn the machine on [8].
Check the air pressure with the purge test button.
Unlock the control [14] – pull control towards you and
by turning to the right or left to set proper pressure.
WARNING
The recommended pressure value for a high-quality is
5,5 bar.
WARNING
“Safety” function in torch – The button cover that prevents
accidental ignition of the torch.
WARNING
The User cannot start a process, if the starts the
equipment with the button in the torch is pressed.
Check process by Active Button Control [19]. For grid
process you can adjust the plasma arc torch time
between 1-5 seconds. The default time is 3 seconds.
Press the control again to confirm your selection.
WARNING
Gouging is only possible with a 230V supply voltage!
Output current range 30-45A.
Press the “Home” button [18] to return to the main
view.
Set the cutting value by the control [19] and turn it to
the left or right to set the value.
The equipment is now ready.
WARNING
To start the process just press the torch button, making
sure you are not aiming the torch air blow towards people
or foreign objects.
By applying the principle of occupational health and
safety, process can be begun.