English 12 English
PRESTOJET 45 – cut
After pressing the button in the torch:
Preflow – purge flow before ignition of the pilot current
– 2s (unalterable).
Pilot current – maximum 3s, if it does not touch the
material or the button in the torch is released, the pilot
current will automatically turn off.
Cutting current – proper cutting – lasts as long as the
button in the torch is pressed.
Postflow – gas flow after cutting – time depends on
the current – see Table 3.
15-30A
30-40A
40-45A
15s
20s
25s
PREFLOW
PILOT
CUTTING CURRENT
2s
3s
POSTFLOW
CUT
PRESTOJET 45
Figure 10
PRESTOJET 45 – grid
After pressing the button in the torch:
Preflow – purge flow before ignition of the pilot current
– 2s (unalterable).
Pilot current – maximum 3s, if it does not touch the
material or the button in the torch is released, the pilot
current will automatically turn off.
Cutting current – proper cutting – lasts as long as the
button in the torch is pressed.
Grid time – sustaining the pilot current, possible only
the button in torch is pressed. Enables the transition
between the materials to be cut. Adjustment range:
1 – 5s.
Postflow – gas flow after cutting – time depends on
the current – see Table 3.
1-5s
GRID TIME
PREFLOW
PILOT
CUTTING CURRENT
2s
3s
POSTFLOW
GRID
PRESTOJET 45
15-30A
30-40A
40-45A
15s
20s
25s
Figure 11
PRESTOJET 45 – gouging
After pressing the button in the torch:
Preflow – purge flow before ignition of the pilot current
– 2s (unalterable).
Pilot current – maximum 3s, if it does not touch the
material or the button in the torch is released, the pilot
current will automatically turn off.
Gouging current – lasts as long as the button in the
torch is pressed.
Pilot – sustaining the pilot current (grid process). Is
only possible when the button in torch is pressed.
Postflow – gas flow after gouging – 15s (unalterable).
PREFLOW
PILOT
2s
3s
15s
POSTFLOW
PILOT
GOUGING
PRESTOJET 45
GOUGING CURRENT
Figure 12
Table 3. PRESTOJET 45 – Preflow/Postflow
Preflow
Current
Postflow
2s
15-30 A
15 s
30-40 A
20 s
40-45 A
25 s