English
31
8
DISPLAY
Description
1.3.5.
Enables management of the "Remaining Qty" countdown.
Important
From the maintenance menu (button P2 on the CPU), you can access "Water Filter", "Last
Filter Change", "Remaining Qty" and "Filter Reset".
Filter enabled
yes
1.4.
This menu option allows setting the operating temperature of the boiler.
Boiler 1 temp.
1.4.1.
It allows you to set the temperature that the vending machine keeps for a few minutes after
a beverage has been brewed.
The set value is expressed in centigrade.
Min. Temperature
94
1.4.2.
It allows you to assign the temperature to which the vending machine is brought after a
certain time from the last dispensing, so that the natural lowering of the temperature of the
hydraulic circuits can be compensated.
The set value is expressed in centigrade.
Max. Temperature
102
1.5.
It allows selecting whether the vending machine must operate with its own tank (setting =
YES) or with an external one (or with water network connection).
Water tank
1.6.
The "Stand-by" and "ECO" modes allow reducing the energy consumption of the machine.
It is possible to select one or both modes.
Energy save
1.6.1.
The "Stand-by" mode is activated after some minutes of inactivity which can be set by means
of this menu option. By setting it to zero the function is disabled.
In"Stand-by" mode the coffee and steam boilers are turned off (instant product boiler
remains on) and the display shows the message "Stand-by".
To exit the "Stand-by" mode, press any button or insert some credit.
When normal operation is restored, the boilers are turned on and the vending machine
starts the warm-up phase.
Stand-by timeout
1.7.
This menu allows setting the parameters related to the the preheating operations for the
brew group, the brewing circuits for instant products or the steam dispensing circuit.
Preheating
1.7.1.
It allows enabling (ON/OFF) a pre-heating cycle of the brew group if it remains inactive for a
period of time.
Coffee preheating
00
1.7.2.
It allows enabling a rinse cycle to pre-heat the brew group when turning on the vending
machine and when exiting the "Stand-by" mode if a certain period of time (that can be set at
item "1.7.3") has passed from the last use of the brew group.
The rinse cycle can be stopped by pressing one of the beverage buttons.
Through this menu it is possible to set the quantity of water to be used.
The settable values are:
0 (zero) rinse cycle disabled, from 1 to 200 ml.
The default value is 0.
RINSING
1.7.3.
Through this menu you can set the number of minutes of inactivity after which the initial
pre-heating or rinse cycle of the brew group must be performed.
The settable values are:
from 1 to 60.
The default value is 5.
Delay
1.8.
By setting the "W" value in the product list, hot water will be dispensed.
This menu allows choosing the solenoid valve to be used for dispensing
If the "hot water solenoid valve" kit is installed, set the value to 0 (zero) or select the
solenoid valve operating on the desired circuit among the available ones.
EV Water Assign
0
1.9.
Rinsing time