28
29
Ground coffee dose adjustment
The coffee dose can be adjusted by means of potentiometer R26 on the electronic card (must only be
performed by a Service Centre).
Potentiometer R26 varies the input voltage to the microprocessor from 0 to 5 V.
The following table provides comparisons for dose adjustments:
Voltage (V)
Coffee grinder pulses
Coffee dose (g)
*
0
80
6,8
1
92
7,5
2
97
8,2
3
106
8,9
4
114
9,6
5
122
10,3
Il grinding time on average 1.3 – 1.5 g /sec.
Factory settings are 100 pulses, equal to a dose of approx. 8.5 g
Turn potentiometer R26 anticlockwise to increase the dose of ground coffee (=122 pulses).
Turn potentiometer R26 clockwise to decrease the dose of ground coffee (=80 pulses).
*
The dose varies according to the coffee blend used.