4
5
�
�
�
�
���������������
��� �
��� �
��� �
��� �
��� �
INCANTO RONDO’ test mode
In test mode, faults can be easily identified thus reducing the time required for fault finding procedures.
To enter test mode, the machine must be switched off with the valve closed.
To enter test mode, press the following buttons
The side valve must be closed.
Press buttons 1 and 3
Turn on the machine by means of the rear switch.
Potentiometer 4 in position MINIMUM
Gearmotor anticlockwise rotation (delivery position)
Button 3
Ensure correct anticlockwise rotation of the gearmotor.
Check the noise level of the gearmotor.
Ensure correct lifting of the unit
When the gearmotor has reached the delivery phase, LED 1
illuminates
Pump operation
Button 1 + knob open
Ensure correct operation of the pump.
Check the noise level of the pump.
Check that LED 4 flashes (turbine)
Potentiometer 4 in position MEDIUM
Gearmotor clockwise rotation (rest position)
Button 3
Ensure correct clockwise rotation of the gearmotor.
Check the noise level of the gearmotor.
Ensure correct lowering of the unit
When the gearmotor has reached the rest position, LED 1 illuminates
Boiler resistance absorption
Button 1
Check correct absorption of the boiler by means of an ammeter
EN Incanto DOT.indd
18/05/2005, 12.05
5