5. SERVICE PROGRAMME
ROYAL
Page 12/24
REV.4 SEPT.2003
Saeco International Group
Function
Setting range
Increment
Comments
TOTAL WATER....S2
(ml) Number
Pump system 2
Total water flow volume (in ml) /
not resettable
WATER DESCALING
S2
(ml)
Pump system 2:
Total water flow (in ml) since last
descaling.
Reset: See S1
HOT WATER
FLOW (l/h) 20
(Only in System 2: OFF
for Royal Cappucc.)
6 – 34 1/h
+/- 2 1/h
The pump delivery rate for hot
water can be expressed in litres per
hour.
HOT WATER
PUMP ADJUST. 63000
(Only in System 2: OFF
for Royal Cappucc.)
58,000 - 65,500
+/- 1
The pump delivery rate is adjusted
in relation to the HOT WATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under HOT WATER PUMP
ADJUSTMENT.
TURBOWATER
FLOW (l/h) 20
(Only in System 2: ON)
only Royal Cappucc.)
6 - 34 1/h
+/- 2 1/h
The pump delivery rate for
turbowater can be expressed in
litres per hour.
(only active when System 2 steam
cycle is active; mixes with hot
water System 1 and System 2)
TURBOWATER
PUMP ADJUST. 63000
(Only in System 2: ON)
(only Royal Cappucc.)
58,000 - 65,500
+/- 1
The pump delivery rate is adjusted
in relation to the TURBOWATER
FLOW setting by means of a phase
controlled modulator. Pump
tolerances can thus also be
adjusted. An equivalent value is
saved under TURBOWATER
PUMP ADJUSTMENT.
Only when System 2 is activated.
WATER RESERVE
NUMBER
No. of PULSES
NUMBER
From Version: 2003
1-2500
When the water tank is full, the
value from WATER RESERVE
STOP is applied. The flow meter
pulses are counted from when the
reed switch is switched and
deducted from the value. If a
beverage is chosen for which the
saved pulse number is higher than
the remaining pulses, the message
FILL WATER TANK appears.
Summary of Contents for Classic
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 16: ......
Page 18: ......
Page 44: ......
Page 46: ......
Page 70: ......
Page 95: ...Saeco International Group REV 4 SEPT 2003 CHAPTER 6 FAULTS Page 1 Faults 1...
Page 96: ......
Page 100: ......
Page 102: ......
Page 116: ......
Page 120: ......
Page 141: ...Saeco International Group REV 4 SEPT 2003 CHAPTER 10 CIRCUIT DIAGRAMS...
Page 142: ......
Page 143: ......