7. FAULT DIAGNOSIS
Saeco International Group
REV.5 SEPT.2004
Page11/12
2.5 Coffee Beans Low indicator
Coffee beans low
Is coffee bean container
empty?
Does coffee dispensing stop
after grinding (coffee beans low
signal again)?
Fill
END
Does coffee have enough froth /
Do dregs have correct
consistency?
Set coarser grind
- Is coffee dispensing
complete?
Replace electronic
system
END
Yes
Yes
No
Yes
Yes
END
END
Grind can be made
coarser
No
No
Yes
Does grinder motor
work after start button
has been activated?
No
Does current reach grinding motor
at a specific time?
No
Replace motor
END
Yes
No
Replace grinding disc
END
Yes
No
Yes
No
Lock motor retainer
into place - END
Test motor retainer -
OK?