SOUTHERN AVIONICS COMPANY
SE Series Installation and Setup
6-5
System Site Configuration
After making any changes, click the
Set
button to send the value to the
Transmitter Control
board.
Click the
Back
button to close the
Transmitter Setup
window and return to the
Main
window.
CAUTION:
Verify beforehand any frequency selected is within the Filter/Bridge modules configuration limits
as described below:
Figure 6-3. SE Transmitter Drawer Diagram
The Filter/Bridge PCB includes a modified 10 element Butterworth-Cauer low pass filter capable
of more than 60dB harmonic attenuation, a broadband RF power bridge, a modulation envelope
detector and associated level sampling circuitry. The entire PCB is enclosed in a metal
enclosure to form a module. The module is available in three different bands, Standard (190-
650kHz), Medium (500-1250kHz) and High (1500-1800kHz).
The Standard and Medium band filters are further subdivided as follows:
Standard Band: 190-300kHz, 300-450kHz and 450-650kHz
Medium Band: 500-750kHz, 700-950kHz and 900-1250kHz
These sub-bands are selected using on board jumpers, JP1 – JP10 as indicated in the tables
below.
SDE33200 Rev 1