SOUTHERN AVIONICS COMPANY
SE Series Installation and Setup
7-7
Operational Checks
7.9.6
Enter the desired frequency of operation using the numeric keypads then press
ENTER
to store
the selection. (If necessary press the
FREQ
key repeatedly to clear the RF frequency field).
7.9.7
Press the
TONE
key to toggle between 400 HZ and 1020 HZ modulation frequency.
7.9.8
Enter the desired call-sign using the numeric keypads then press
ENTER
to store the selection.
Press the
CALL SIGN
key to open the
CALL SIGN ENTRY
menu, as shown below. (If necessary
press the
FREQ
key repeatedly to clear the RF frequency field).
7.9.9
Press the
MODE
key to toggle the CARR, IDENT, CONT. to Carrier Mode (Carr).
7.9.10
Press the
OUTPUT POWER
key to open the
RF POWER SETTING
menu, as shown below.
RF FREQUENCY ENTRY
FREQ should be between 190K and 1800K Hz
Enter RF Frequency: [ 320000] Hz
CALL SIGN ENTRY
Maximum 8 Characters
Entry Call Sign: SAC