12
Energy Smart |
FAST UNIT SELECTION
Energy Smart units are suitable for operation in balanced or slightly unbalanced flow and return conditions. They ensure
residential air exchange, recovering the heat from the extracted air and conveying it to the clean air. The chart below shows the
recommended operating ranges in terms of volumetric supply air flow rate at standard conditions and available external static
pressure.
Pro ENY-SP Vertical Version
CERTIFIED
COMPONENT
Passive House Institute
cool, temperate climate
LEGEND
| all terms must be considered in compliance with Standard EU 1253/2014
Q
max
Maximum flow rate, at max. motor speed and external static pressure of 100 Pa
SEC
Specific energy consumption
Q
ref
Reference flow rate - 70% of Q
max
L
WA
Sound power level emitted by structure
P
el
Power supply at Q
ref
and external static pressure of 50Pa
LK
I
Internal leakage at 100 Pa compared to Q
ref
ηt
_rvu
Thermal efficiency at Q
ref
LK
E
External leakage at 250 Pa compared to Q
ref
SPI
Specific power input
HEP
Pre-heater power (only mod. SPEL, SPER)
CTRL
Control factor - Centralised automatic control
C
M
Y
CM
MY
CY
CMY
K
grafico pag10.pdf 1 16/12/20 09:38
C
M
Y
CM
MY
CY
CMY
K
grafico pag10.pdf 1 16/12/20 09:42
Ex
ternal sta
tic P
ressur
e [P
a]
Air Flow [m
3
/h]
ENY-SP-180
ENY-SP-280
ENY-SP-370
ENY-SP-460
ENY-SP-600*
Q
max
[m
3
/h]
180
280
370
460
600
Q
rif
[m
3
/h]
130
200
260
320
420
P
el
[W]
23
35
47
76
105
ηt
_rvu
[%]
91,5%
91,4%
92,5%
88,6%
88,00%
SPI
[W/m
3
/h]
0,174
0,174
0,179
0,237
0,247
CTRL
-
0,85
0,85
0,85
0,85
0,85
SEC
[kWh/m
2
a]
-42,32
-42,29
-42,47
-40,10
-39,71
Energy class
A+
A+
A+
A
A
Filter efficiency
ePM
1
55% - F7
ePM
10
50% - M5
ePM
1
55% - F7
ePM
10
50% - M5
ePM
1
55% - F7
ePM
10
50% - M5
ePM
1
55% - F7
ePM
10
50% - M5
ePM
1
55% - F7
ePM
10
50% - M5
L
WA
[dBa]
38,9
43,1
46,3
47,9
52,4
LK
I
[%]
1,2%
0,7%
0,5%
0,3%
0,60%
LK
E
[%]
1,7%
1,0%
0,8%
0,7%
1,84%
HEP
[W]
500
900
1250
1600
2000
*
= not Passivhaus certified unit
Summary of Contents for ENY-SP-180
Page 2: ...Energy Smart...
Page 4: ...Energy Smart 2...
Page 17: ...15 Energy Smart...
Page 25: ...23 Energy Smart Vertical Version ENY SP and ENY S Versions 12 5 4 3 2 1 11 10 9 8 7 6...
Page 45: ...43 Energy Smart Horizontal Version Pro ENY SHP 150 Version 3 1 2 7 9 11 10 4 6 8 5...
Page 47: ...45 Energy Smart Horizontal Version Pro ENY SHP 170 Version 1 2 3 5 4 3 7 10 9 11 5 6 8...
Page 49: ...47 Energy Smart Horizontal Version Pro ENY SHP 270 Version 1 2 3 4 7 10 9 11 5 6 8...