365 / Instruction #8920101 Rev 4
Pg. 8
Fig. 10
Base and Cable Tie Down Floor Anchor Installation
Note: 8 anchors in total for this assembly, drill & install anchors as described on page 7.
1.
Mark out the location of the 4-Cable Tie-down anchors using the dimensions shown below (Fig. 10).
Use the Diagonal Measurement (11’ 7”) to ensure the 4 anchors are square to each other. Install the
Floor anchors, as explained on page 7 Installing Anchors. Then install Threaded Socket Adaptors.
2.
Next Center the cantilever assembly within this anchor pattern. Use the holes in the base legs as
guides for drilling the 4 upright base anchors, as explained on page 7 Installing Anchors. Install the
Anchors and fasten the Bases Down. Replace plastic caps in the base leg holes after installation.
3.
Attach the tie down cables using the quick links to the top of each Cantilever Upright & tighten
Quick links using 2 adjustable wrenches, then secure the other end to the turnbuckle hook and chain
to the Threaded Socket Adaptors (floor anchors) and. See Figure 11 below for connection points.
4.
Once all 4 cables are connected properly, the cables can be tightened using the turnbuckles. Tighten
each Turnbuckle equally so that the uprights remain perpendicular to the floor. See next section for
complete instructions on rail and turnbuckle adjustments.
Ensure the floor Anchors are properly set or the safe use of the equipment may be compromised
Fig. 11
TURNBUCKLE CONNECTION TO
THREADED SOCKET ADAPTORS
(FLOOR ANCHORS)
QUICK LINK CONNECTION
TURNBUCKLE
Do not over tighten the turnbuckles as this
may warp or damage the uprights, see note
on subsequent page, about Adjustments.
THREADED SOCKET
ADAPTORS (4)
CABLE TIE DOWN FLOOR ANCHORS (4)
BASE LEG
HOLE
BASE LEG ANCHORS (4)
FLOOR ANCHOR
(THREADED SOCKETS)