S+S Regeltechnik THERMASGARD HFTM-VA Series Operating Instructions, Mounting & Installation Download Page 2

THERMASGARD

® 

HFTM - VA 

D G F r

KL

ø 

6

50

KL

ø 

6

50

M20x1.5

M12

11

2

11

0

97

143

61

126

8.8

17

126

8.8

17

KL

ø 

6

50

KL

ø 

6

50

M20x1.5

M12

11

2

11

0

97

143

61

126

8.8

17

126

8.8

17

KL

ø 

6

50

KL

ø 

6

50

M20x1.5

M12

11

2

11

0

97

143

61

126

8.8

17

126

8.8

17

Maßzeichnung

Dimensional drawing

 

Plan coté 

Габаритный чертеж

HFTM - VA 

Gehäuse mit 

M12-Steckverbinder 

Housing with 

M12 connector

Boîtier avec 

connecteur M12

Корпус с 

разъемом M12

Gehäuse mit 

Kabelverschraubung

Housing with 

cable gland

Boîtier avec 

presse-étoupe

Корпус с 

резьбовым кабельным вводом

IP 54   

(optional)

 

mit 

Glasseide

-Kabel

(optional)

 

with 

glass fibre 

cable

(en option)

 

avec câble en 

fibre de verre

(опционально)

 

с кабелем из 

стеклонити

IP 68

(optional)

 

wasserdicht 

Perfect Sensor Protection

(optional)

 

watertight 

Perfect Sensor Protection

(en option)

 

étanche à l'eau 

Perfect Sensor Protection

(опционально)

 

водонепроницаемый 

Perfect Sensor Protection

IP 65   

(Standard)

 

feuchtedicht 

(standard)

 

humidity-tight

(standard)

 

étanche à l'humidité

стандартное исполнение)

 

влагоотталкивающий

Summary of Contents for THERMASGARD HFTM-VA Series

Page 1: ...rs with temperature measuring transducer calibratable with multi range switching and active output F Notice d instruction Sonde chemis e avec convertisseur de temp rature talonnable avec commutation m...

Page 2: ...erbinder Housing with M12 connector Bo tier avec connecteur M12 M12 Geh use mit Kabelverschraubung Housing with cable gland Bo tier avec presse toupe IP54 optional mit Glasseide Kabel optional with gl...

Page 3: ...er 5 polig A Kodierung nach DIN EN 61076 2 101 Geh use aus Edelstahl V4A 1 4571 mit verzugfreier Deckelverschraubung schlagfest hohe EMV St rfestigkeit korrosions temperatur witterungs und UV best ndi...

Page 4: ...C Versorgungsspannung betrieben ist der Be triebsspannungseingang UB f r 15 36 V DC Einspeisung und UB bzw GND als Masseleitung zu verwenden Werden mehrere Ger te von einer 24 V AC Spannung versorgt i...

Page 5: ...e und Bedie nungsanleitung Abweichungen zur Katalogdarstellung sind nicht zus tz lich aufgef hrt und im Sinne des technischen Fortschritts und der ste tigen Verbesserung unserer Produkte m glich Bei V...

Page 6: ...e 5 pin A code according to DIN EN 61076 2 101 Housing stainless steel V4A 1 4571 with non distortion cover bolting impact resistant high EMI shielding corrosion temperature weather and UV resistant H...

Page 7: ...e When this device is operated on DC supply voltage the operating voltage input UB is to be used for 15 36 V DC supply and UB or GND for ground wire When several devices are supplied by one 24 V AC vo...

Page 8: ...l only be used for their intended purpose Respective safety regulations issued by the VDE the states their control authorities the T V and the local energy supply company must be observed The buyer ha...

Page 9: ...2 m le 5 p les codage A selon DIN EN 61076 2 101 Bo tier en acier inox V4A 1 4571 avec raccordement viss du couvercle r sistant la d formation et aux chocs r sistance aux interf rences CEM lev e r sis...

Page 10: ...t UB ou GND comme c ble de masse Si plusieurs appareils sont aliment s en 24V ca il faut veiller ce que toutes les entr es de tension positives des appareils de terrain soient reli es entre elles de m...

Page 11: ...pprovisionnement en nergie locales sont respecter L acheteur doit respecter les dispositions relatives la construction et la s curit et doit viter toutes sortes de risques Les d fauts et dommages r su...

Page 12: ...MASGARD HFTM VA 8 V4A M12 DIN EN 61076 2 101 THE 24 10 U 15 36 I 0 3 Ra Ub 14 0 02 I RL 5 U 1 0 24 2 2 24 100 20 C 500 Pt1000 DIN EN 60751 Perfect Sensor Protection IP68 8 10K 0 2 K 25 C 0 10 4 20 A 2...

Page 13: ...supply AC 24V 0V DC 15 36V GND Circuitry 0 10V 0V GND V Power supply AC 24V 0V DC 15 36V GND 800 700 600 500 400 300 250 50 200 10 15 20 25 30 35 36 40 Load resistance diagram Working resistance Ohm O...

Page 14: ...r EMV VDE VDI DDC PLC 0 5 g 0 10 0 10 4 20 mA 4 20 4 VDE r ZVEI VDE EMV...

Page 15: ...et de modifications techniques Toutes les informations correspondent l tat de nos connaissances au moment de la publication Elles servent uniquement informer sur nos produits et leurs possibilit s d a...

Page 16: ...Passive sensor Passive sensor UB 24 V DC Output 4 20 mA in C Internal sensor optional Internal passive sensor optional DIP switches Measuring range changeover max min 10K Offset 12 3 1 2 4 5 3 ON Pas...