The pressure measuring transducer
PREMASGARD
®
SHD-LC
measures relative pressures in the bar range.
It converts the measurand pressure into standard signals of 0 -10 V or 4...20 mA. Process connection is G ½ " straight external pipe thread.
SHD-LC is used for pressure measurement in gaseous and liquid media. Applications of this pressure transmitter are in hydraulics,
pneumatics, process technology, in mechanical and plant engineering.
Not applicable for ammonia and Freon!
TECHNICAL DATA:
Power supply: ........................ 24 V AC ⁄ DC for output 0 -10 V
7 - 33 V DC for output 4 ... 20 mA
Measuring ranges: .................. see table
(other ranges upon request)
Output signal: ........................ 0 -10 V, 3-wire, (working resistance > 10 kOhm) or
4... 20 mA, 2-wire, (working resistance < (UB (V) -7 V) ⁄ 0,02 A ;
R
L
depending on working resistance
Electrical connection: .............. plug connector DIN EN 175301-803-A
Pressure connection: ............... G ½ " sealing at the back,
and manometer (combined) with profile gasket FPM,
special WW G ¼ " DIN 3852
Type of pressure: .................... relative
Measuring principle: ................
ceramic measuring cell
Temperature of medium: .......... –15...+ 125 °C
Mounting: .............................. directly on pressure line
Enclosure: ............................. stainless steel 1.4305
Connecting head: .................... plastic, approx. 98 x 50 x 34 mm
Medium contacting parts:......... stainless steel type 1.4305, AISI 303;
measuring element ceramic Al
2
0
3
(96%);
sealing material FPM (Viton)
Response time: ...................... 2 ms (1 ms typical)
Load changes: ........................ < 100 Hz
Characteristic line: ................. ± 0.3 %
Overload range/
Bursting pressure: .................. < 4 bar: 3 x FS
> 4 bar: 2.5 x FS
Protection class: .................... III (according to EN 60 730)
Protection type: ..................... IP 65 (according to EN 60 529)
Standards: ............................ CE conformity, electromagnetic compatibility
according to EN 61 326, EMC directive 2004 ⁄ 108 ⁄ EC
ACCESSORIES: ....................... incl. receptacle DIN EN 175301-803-A
G
PREMASGARD
®
SHD - LC
Rev. 2015 - 1.0 GB
Connecting diagram
SHD - LC - U
Connecting diagram
SHD - LC - I
1
2
3
IN
+
–
OUT
GND
3
2
1
Output pressure 0-10V
GND
Supply voltage
UB+ 24V AC/DC
3
2
1
1
2
3
IN
+
–
OUT
Output pressure 4...20mA
Free
Supply voltage
UB+ 24V DC
Type ⁄ WG1
Measuring
Range
Item No.
SHD -LC - U
U - variant
SHD -LC -U 6
0 … 6 bar
1301-2121-0550-120
SHD -LC -U 10
0 …10 bar
1301-2121-0560-120
SHD -LC -U 16
0 …16 bar
1301-2121-0570-120
Type ⁄ WG1
Measuring
Range
Item No.
SHD -LC - I
I - variant
SHD -LC -I 6
0 … 6 bar
1301-2122-0550-000
SHD -LC -I 10
0 …10 bar
1301-2122-0560-000
SHD -LC -I 16
0 …16 bar
1301-2122-0570-000
Summary of Contents for PREMASGARD SHD