S P E C I F I C A T I O N S 

ELECTRICAL RATINGS

Input Voltage required: 120VAC 60Hz
Input: 120VAC, 60Hz, 1.2A max
Output: 12-13 VAC, 60 Watts (x2) max

CONSTRUCTION

Case:  High Impact Polycarbonate
Acoustic rating:  0dB(A)
Weight: 13.5 lbs.

Ambient Temp: 40°C +10/-40  

Maximum Soil Height: 
Do NOT allow fill to 
exceed this level

Optional PT-BASE for 
new installations or when 
previous 2000/6000 
Series illuminator base is 
not available.

CAUTION:

 THE EQUIPMENT AND 

CONTROLS SHALL BE LOCATED NOT 
LESS THAN 1 M HORIZONTALLY 
FROM THE SPA OR HOT TUB 

ATTENTION:

 MAINTENIR UNE 

DISTANCE MINIMALE, MESURÉE 
DANS UN PLAN HORIZONTAL, DE 1 M 
ENTRE LA CUVE DE RELAXATION ET 
LES APPAREILS ET COMMANDES 

Summary of Contents for Power Tower PT-6002

Page 1: ...stallation Instructions Read all instructions before attempting to perform installation work FOR USE WITH POOL AND SPA PRODUCTS 79 15280 01 Rev A0 4008814 ETL LISTED Conforms to UL STD 379 Certified t...

Page 2: ...2...

Page 3: ...ORMATION 4 FCC WARNING 4 SPECIFICATIONS 5 INSTALLATION GUIDELINES 6 STAND ALONE ENVIRONMENT OPERATION 9 INSTALLING THE PT 6002 UNIT TO THE PT BASE 9 ELECTRICAL PROTECTION MEASURES 10 WIRELESS REMOTE O...

Page 4: ...n to operate the PT 6002 unsupervised F C C W A R N I N G 1 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful...

Page 5: ...nt Temp 40 C 10 40 Maximum Soil Height Do NOT allow fill to exceed this level Optional PT BASE for new installations or when previous 2000 6000 Series illuminator base is not available CAUTION THE EQU...

Page 6: ...h with the port but extend no more than 1 above it b 12VAC output conduit Cables from the lights must all come through the larger of the two ports in the PT Base as pictured in Figure A This conduit s...

Page 7: ...6 Connect each wire to its correct segment Figure B a Fully insert the wire installation tool supplied into the segment s smaller square hole b Firmly lever the tool to the left to open the wire entry...

Page 8: ...ad through the outermost hole and the red insulated lead through the innermost hole as shown 6 While holding both leads fully inserted flip both levers all the way up 7 Pull on each lead firmly to con...

Page 9: ...on Remote On Off Operation Move the power switch to the lower remote position and use the hand held remote to toggle the low voltage power circuit on and off See below for remote button functions and...

Page 10: ...nce normal operating temperatures return the unit will reset and operation will continue 2 Replaceable Current Fuse To protect against hazardous electrical conditions the PT 6002 utilizes a current fu...

Page 11: ...Turn On Using the Wireless Remote Operation Zone 2 Push the button marked 2 ON OFF COLOR CHANGE to toggle on and off the power of Zone 2 on the PT 6002 Color Changing Operation To change LED pool ligh...

Page 12: ...teps as outlined below 1 Shut off power at the appropriate circuit breaker remove all chances of accidental electrical shock 2 Remove lift off cover to allow access inside the PT 6002 3 Find the 5cm a...

Reviews: