Attention:
Working on live equipment is forbidden.
INSTALLATION GUIDANCE
The reactor control panel utilises air cooling. The following guidelines must be adhered to when
locating the unit.
The reactor and control panel must not be located in a position where the ambient air temperature
exceeds 40ºC.
The reactor and control panel must not be located adjacent to other equipment that directly emit
heat
The reactor and control panel must not be located adjacent any chemical equipment that is likely
to emit fumes.
The reactor should be located within the piping system in such a manner as to ensure that
sufficient clearance is available in a horizontal direction to allow for lamp replacement and wiper
maintenance. See the relevant data information included in this manual.
The reactor must be positioned with the side flanged pipe connections pointing in an upwards
direction.
Never install the reactor in a position directly adjacent to chemical dosing points.