Page 43 / 60
SISE_M_REGUL_Serie M_MV3-IM_MV3-TS_V7.3_20200108_B_En
www.sise-plastics.com
Through the mold monitoring screen the user can quickly assess the operation and consumption of the
control system.
For monitoring to be e
ff
ective, the calculated values must be taken as reference values.
The mold monitoring screen is accessible in the "Control" view
.
Temperature monitoring
Power monitoring
Heating element monitoring
Sub-menu
Mold monitoring o
ff
ers 3 tables, the
fi
rst column of which contains the zones by groups.
These details can be viewed zone by zone, by pressing "
" on the line of a particular group.
The "Zones without group" line is associated with zones which have not been assigned to a group.
The "All zones" line gives details of all the zones of the system, providing information on the system’s
total consumption.
"Temperature monitoring" table
:
Low and High Temperature Alarms can be viewed and set in this table. Temperature monitoring limits
and current temperature are shown. The latter is colored red in case the zone is outside its tolerance.