A
and E
ramp gradients
:
A and E ramp gradients determine the heating / cooling gradient and thus the instantaneous power
consumption. Settings will therefore be done according to criteria of technical necessity and the need to
limit the peak current during heating.
Optimized power consumption AND non-optimized heating time.
Moderately optimized power consumption AND optimized heating time.
Unlimited power consumption AND heating time reduced to a minimum.
Uncontrolled cooling time.
Optimized cooling time.
Maximum cooling time.
Power restriction
:
In all four start-up modes power is limited to 15% at the start of the ramp for 1 minute or until the zone
reaches 100°C.
3.1.2.3)
H
eating zone con
fi
guration
Heating zones can be con
fi
gured from the "Control" page or from the "Zone con
fi
guration table" (§3.1.2.5).
The "Control" screen is accessible in the "Control" view
.
To con
fi
gure a heating zone, press it twice ("double-click" on it) or press the Zone con
fi
guration icon
.
To con
fi
gure more than one heating zone simultaneously, select a number of zones (§2.3.3) and press
one of them twice ("double-click"). This zone then becomes the "reference zone".
This brings up the Zone con
fi
guration screen:
Selected zones