- 28 -

9. LISTE DES PIECES DE RECHANGE ET APERÇU DES COMPOSANTS

NG

Pos.

Désignation

15

No. d’art.

35

No. d’art.

50

No. d’art.

75

No. d’art.

100

No. d’art.

1

Brûleur

100072

101378

101378

100504

100504

2

Interrupteur de commande

100994

100994

100994

100994

100994

3

Interrupteur thermique

101170

-----

-----

-----

-----

4

Grille de protection avant

100766

100768

100768

100983

100983

5

Sécurité d’allumage thermoélectrique

101993

-----

-----

-----

-----

6

Thermoélément

101994

-----

-----

-----

-----

7

Câble d’allumage

102346

1-00535

1-00535

1-00535

1-00535

8

Moteur

102450

102384

102384

-----

-----

9

Vanne électromagnétique

102471

102471

102471

101141

101141

10

Roue de ventilation

102661

102389

102389

-----

-----

11

Disjoncteur de courant
thermoélectrique

102814

-----

-----

-----

-----

12

Electrode d’allumage

103314

103312

103312

103311

103311

13

Piézoallumage

103315

-----

-----

-----

-----

14

Réglage de l’appareil

103040

103040

103040

103040

103040

15

Limitateur de température de sécurité
STB

-----

100219

100219

100219

100219

16

Brûleur à gaz automatique DVI

-----

103946

103946

103946

103946

17

Electrode d’ionisation

-----

1-00529

1-00529

1-00529

1-00529

18

Condensateur de dépannage

-----

1-00394

1-00394

1-00394

1-00394

19

Condensateur 5 µF

-----

-----

-----

101377

101377

20

Prise du thermostat

102715

102715

102715

102715

102715

21

Kit gaz  02-048-26

103358

103358

103358

103358

103358

22

Ventilateur

-----

-----

-----

102394

101152

23

Câble d’ionisation

-----

1-00536

1-00536

1-00536

1-00536

24

Capteur de dépannage

-----

103718

103718

103718

103718

Pour les réparations, veuillez utiliser uniquement les pièces d’origine du fabricant !

Summary of Contents for NG-100

Page 1: ...0 Betriebsanleitung Operating Instructions Mode d utilisation NG 15 35 50 75 100 Gustav Nolting GmbH Neuzeitliche Heiztechnik...

Page 2: ...stellung Montage Seite 3 4 5 Inbetriebnahme Seite 4 6 Ausserbetriebnahme Seite 4 7 Wartungsarbeiten Seite 4 8 M gliche St rungen und deren Ursachen Seite 5 9 Ersatzteillisten und Bauteile bersicht Sei...

Page 3: ...druck bar 2 5 10 0 2 5 10 0 2 5 10 0 2 5 10 0 2 5 10 0 Anschlu wert kg h 0 54 1 09 1 41 2 73 1 95 3 91 2 73 5 47 3 91 7 81 Stromaufnahme A 0 48 0 48 0 48 0 60 0 92 L nge mm 500 500 650 800 1 000 Breit...

Page 4: ...onisationselektrode dient als Flammen berwachung und ist an einen Gas feuerungsautomaten angeschlossen der die Gesamtfunktion des WLE steuert und berwacht 4 AUFSTELLUNG MONTAGE Um Personen und Sachsch...

Page 5: ...ebungstemperatur einge stellt werden Mit dem Ventilator wird die Z ndung automatisch eingeschaltet und nach einer kurzen Vorsp lzeit das Magnetventil Pos 9 ge ffnet Nach der Flammenbildung wird die Z...

Page 6: ...lt zu gro Z ndkabel defekt Pos 7 Gasfeuerungsautomat defekt Pos 16 Austauschen Verkleinern Austauschen Austauschen WLE l uft an Z ndung ist vor handen Magnetventil ffnet Gas str mt ein wird entz ndet...

Page 7: ...11 Thermostromunterbrecher 102814 12 Z ndelektrode 103314 103312 103312 103311 103311 13 Piezoz nder 103315 14 Ger teregler 103040 103040 103040 103040 103040 15 Sicherheitstemperaturbegrenzer STB 100...

Page 8: ...7 NG 15 35 50...

Page 9: ...8 NG 75 100...

Page 10: ...9 11 ELEKTRISCHER SCHALTPLAN Ger tetyp NG 15...

Page 11: ...10 11 ELEKTRISCHER SCHALTPLAN Ger tetyp NG 35 50...

Page 12: ...11 11 ELEKTRISCHER SCHALTPLAN Ger tetyp NG 75 100...

Page 13: ...sembly Page 14 15 5 Initial operation and further start ups Page 15 6 Placing out of service Page 15 7 Maintenance Page 15 8 Possible malfunctions and their causes Page 16 9 Spare Parts List and Compo...

Page 14: ...on pressure bar 2 5 10 0 2 5 10 0 2 5 10 0 2 5 10 0 2 5 10 0 Connected load kg h 0 54 1 09 1 41 2 73 1 95 3 91 2 73 5 47 3 91 7 81 Power consumption A 0 48 0 48 0 48 0 60 0 92 Length mm 500 500 650 80...

Page 15: ...he automatic gas firing unit that controls and monitors the overall function of the WAH 4 INSTALLATION ASSEMBLY In order to prevent personal injury and property damage the relevant local building fire...

Page 16: ...om thermostat the thermostat must be set using room temperature With fan ignition is automatically turned on and after a short pre purge time the solenoid Item 9 is opened After establishing the flame...

Page 17: ...nition gap too large Ignition cable defective Item 7 Automatic gas firing unit defective Item 16 Replace Reduce Replace Replace WAH starts ignition present solenoid valve opens gas flows in is ignited...

Page 18: ...l 102661 102389 102389 11 Thermo circuit breaker 102814 12 Ignition electrode 103314 103312 103312 103311 103311 13 Piezo igniter 103315 14 Device controller 103040 103040 103040 103040 103040 15 Safe...

Page 19: ...18 NG 15 35 50...

Page 20: ...19 NG 75 100...

Page 21: ...20 11 ELECTRICAL CIRCUIT DIAGRAM Device Type NG 15...

Page 22: ...21 11 ELECTRICAL CIRCUIT DIAGRAM Device Type NG 35 50...

Page 23: ...22 11 ELECTRICAL CIRCUIT DIAGRAM Device Type NG 75 100...

Page 24: ...llation Assemblage Pages 25 26 5 Mise sous tension Page 26 6 Mise hors tension Page 26 7 Maintenance Page 26 8 Les dysfonctionnements possibles et leurs causes Page 27 9 Liste des pi ces de rechange e...

Page 25: ...n du gaz l entr e bar 2 5 10 0 2 5 10 0 2 5 10 0 2 5 10 0 2 5 10 0 D bit de gaz kg h 0 54 1 09 1 41 2 73 1 95 3 91 2 73 5 47 3 91 7 81 Consommation de courant A 0 48 0 48 0 48 0 60 0 92 Longueur mm 50...

Page 26: ...er des dommages personnels et mat riels les r gulations en vigueur relatives la construction la protection contre les incendies ainsi que les stipulations des associations professionnelles sont respec...

Page 27: ...p rature ambiante L allumage est enclench en m me temps que le ventilateur et apr s un bref d lai de pr rin age la vanne lectromagn tique s ouvre pos 9 Lorsque la flamme est allum e l allumage s teint...

Page 28: ...trop grande C ble d allumage d fectueux pos 7 Br leur gaz automatique d fectueux pos 16 Remplacez R duisez Remplacez Remplacez Le GAC d marre l allumage s enclenche la vanne lectromagn tique s ouvre l...

Page 29: ...Disjoncteur de courant thermo lectrique 102814 12 Electrode d allumage 103314 103312 103312 103311 103311 13 Pi zoallumage 103315 14 R glage de l appareil 103040 103040 103040 103040 103040 15 Limitat...

Page 30: ...29 NG 15 35 50...

Page 31: ...30 NG 75 100...

Page 32: ...31 11 SCHEMA DES CONNEXIONS ELECTRIQUES Type d appareil NG 15...

Page 33: ...32 11 SCHEMA DES CONNEXIONS ELECTRIQUES Type d appareil NG 35 50...

Page 34: ...33 11 SCHEMA DES CONNEXIONS ELECTRIQUES Type d appareil NG 75 100...

Page 35: ...derger tebau Blechbearbeitung Our Comprehensive Supply Program Warm Air Heaters System Construction Air Ducts Fans for air supported domes and other flexible structures Control Systems Construction Li...

Reviews: