3.3 Product

The following device variants of the con::cube are available. Regarding detailed information of the device variants, please refer 

to the technical specifications located at the end of this manual.

Type

Specification

D-330-230

Station control terminal with 100-240 VAC, 50-60 Hz power supply

D-330-024

Station control terminal with 10-36 VDC power supply

D-330-TOUCH

Display and touch screen input module

D-315-3GLX

3G modem (OS Linux)

D-315-OUT-PROFIBUS

Profibus DP (output module)

D-315-OUT-SDI12

SDI 12 (output module)

D-315-OUT-MA

2 analog outputs (output module)

D-315-OUT-RELAY

4 digital outputs (output module)

D-315-IN-MA

2 analog inputs for integration of third party readings (input module)

D-315-IN-RELAY

2 digital inputs for integration of third party readings (input module)

D-315-ANTENNA-PLUG

internal antenna adapter cable and connector

D-315-ANTENNA-PRO

external, high range antenna, incl. 10 m extension cable

D-303-LX

Licence Linux application (fix installed OS)

S-20-MVA

Complete license including moni::tool (all features), vali::tool and ana::tool

The device is typified by a type label, as shown on the right, that contains the following information:

  Manufacturer’s name and country of origin

  Several certification marks

  Device name (con::cube)

  Type of power supply

  Bar code

  Device serial number (S/N)

  Information on power supply

  Environment rating (IP)

  Acceptable humidity limits 

  Acceptable temperature limits 

  Item number (Type) 

  QR code 

con::cube D-330, 01-2020 Release

Copyright © s::can Messtechnik GmbH

www.s-can.at

8 / 42

Summary of Contents for con::cube D-330

Page 1: ...Manual con cube D 330 January 2020 Release S 45 M...

Page 2: ......

Page 3: ...Mode 16 6 Operation of con cube 17 6 1 Direct Operation of con cube 17 6 2 Remote Operation of con cube 17 6 2 1 Remote Operation of con cube via Web Browser 17 6 2 2 Remote Operation of con cube via...

Page 4: ...Cleaning 35 11 2 1 Cleaning Valve 35 11 3 Spare Parts 35 11 3 1 Desiccant Package 35 11 3 2 Touch Pen 35 11 4 Optional Features 36 11 4 1 Gateway to 3G Modem 36 11 4 2 Analog Output Module 36 11 4 3 D...

Page 5: ...d in English and German by s can This original manual serves as the reference in case discrepancies occur in versions of the manual after translation into third languages This manual and all informati...

Page 6: ...products are leaving our factory in immaculate technical and safety conditions Inappropriate or not intended use of the product however can cause danger The manufacturer is not responsible for damage...

Page 7: ...ia analog input optional Integration of external sensor signals via digital input optional Network connectivity via ethernet WLAN or optional 3G 4G modem Remote control of s can monitoring station via...

Page 8: ...on of third party readings input module D 315 IN RELAY 2 digital inputs for integration of third party readings input module D 315 ANTENNA PLUG internal antenna adapter cable and connector D 315 ANTEN...

Page 9: ...le glands M16 optional for Profibus 3 cable glands M16 1 cable gland M16 optional antenna plug 2 cable glands M20 Holder for housing cover Desiccant package Insert for SIM card Additional cable termin...

Page 10: ...s well as electromagnetic radiation Damage to the device caused by wrong storage will not be covered by warranty Transport should be done in a packaging that protects the device original packaging or...

Page 11: ...an option Cable for power supply part no C 31 xx Gateway to 3G part no D 315 3GLX Internal antenna adapter cable and connector part no D 315 ANTENNA PLUG External antenna part no D 315 ANTENNA PRO Di...

Page 12: ...Best possible weather and splash water proof set up Infrastructure energy data and compressed air Power supply for controller for operation operational reliability voltage power peak free Oil and part...

Page 13: ...1 Plan of Terminal Connections Once the housing cover has been opened four hexagonal head screws removed you have access to the cable terminal compartment of the con cube Opening of the cable terminal...

Page 14: ...ox B 23 xxx has to be used to connect a further spectrometer probe 5 3 Connection of s can ISE Probes and Sensors Alternative or additional to the spectrometer probe it is possible to connect ISE prob...

Page 15: ...arameterised within the moni tool software please refer to manual moni tool 5 5 Connection of Main Power Supply This type of work must be performed by authorised persons only see section 2 Depending o...

Page 16: ...display Please refer to the manual of the operation software moni tool for all further tasks to complete the initialisation of your s can monitoring system 5 7 con cube Sleep Mode For operation with l...

Page 17: ...6 1 Direct Operation of con cube Normally this direct operation is performed by a person standing in front of the con cube and using the touch screen Alternatively moni tool can also be operated with...

Page 18: ...once the remote connection was successful The password to be entered is scan case sensitive If you operate the con cube via VNC Viewer all actions can be seen on the touch screen of the con cube also...

Page 19: ...contains all types of possible connectivity setups Regarding the individual connection types please refer to the subsections afterwards con cube Type of data transfer Connection type Customer infrast...

Page 20: ...cube 192 168 10 12 IP address of the PC 192 168 10 2 Subnet mask for both devices 255 255 255 0 Connect your network cable RJ45 to the con cube and to the PC when working via LAN see section 6 5 1 Al...

Page 21: ...ofile e g by editing the existing Default profile via Service Terminal Network Settings Modem Select Default and push icon Edit Enter a Profile name and the PIN of the SIM card Enter the Apn and the A...

Page 22: ...ich is always OpenVPN Custom Push the button Save Within the next window enter a Profile name Select the file containing the Private key password e g password txt Select the file containing the OpenVP...

Page 23: ...moni tool menu item Service Outputs TML Transfer of measurement result files automatical via FTP see manual moni tool Service Outputs File Output FTP Transfer automatical via SSH see manual moni tool...

Page 24: ...eger 0xXXYY int16 has the following mapping M o d b u s r e g i s t e r Register address b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0 0xXXXX 0xXX 0xYY For example 17289 0xBC77 has the mapping...

Page 25: ...ion Function code Description used for Read Input Register 0x04 Parameter readings Parameter status Device status Read Holding Register 0x03 Device and parameter configuration settings Mirrored input...

Page 26: ...s 0x00C8 bitmask 1 R Para 10 status 1 200 xP10Value 0x00CA float 2 R Para 10 result 202 parameter 11 result bmP11Status 0x00D0 bitmask 1 R Para 11 status 1 208 xP11Value 0x00D2 float 2 R Para 11 resul...

Page 27: ...0x0162 float 2 R Para 29result 354 parameter 30 result bmP30Status 0x0168 bitmask 1 R Para 30 status 1 360 xP30Value 0x016A float 2 R Para 30 result 362 parameter 31 result bmP31Status 0x0170 bitmask...

Page 28: ...not supported or reserved Each bit reperesents a condition 1 error 0 o k M a p p i n g o f P a r a m e t e r S t a t u s b m P x S t a t u s Bit Display xPxValue Status Description b0 NaN or value Ge...

Page 29: ...atus Status of parameter 7 0x2A 0x2D Float xP7Value Reading of parameter 7 0x2E 0x2F Bitmask bmP8Status Status of parameter 8 0x30 0x33 Float xP8Value Reading of parameter 8 0x34 0x40 TAI64n tSampleTi...

Page 30: ...remind that polling of readings needs several seconds Automatic measurement active Readings are actualized Service mode not active Check measuring settings Leave Service mode System status LED is blu...

Page 31: ...have to be checked for cleanliness possible damage and dirt or foreign bodies before closing the housing cover every time In case of damage to the cord gasket 2 in the housing cover it has to be repai...

Page 32: ...rn Material Authorization Return consignments of the s can monitoring system or parts of the system shall be done in a packaging that protects the device original packaging or protective covering if p...

Page 33: ...2 x M8 U bolt with screw nut and spring washer 4 x M5 flange nut included in delivery for mounting onto rails 11 1 2 Power Supply Cord For connection of the device to the power supply a power supply...

Page 34: ...install antenna under large overhanging tree branches The mounting of the antenna is performed by the following steps Fix carrier brackets on mounting console with bolts Fix mounting console antenna...

Page 35: ...2 coupler screw connection 6 4 mm nickel plated brass P inlet pipe compressor compressed air side Connection fitting probe side B 44 Hose ID 3 8 inch B 44 2 plug in fitting 6 mm OD A inlet pipe probe...

Page 36: ...see sec tion 5 1 for correct wiring Configuration via moni tool software see section 12 1 for address mapping Assembling only by qualified personal authorized by s can con cube can be equipped with ma...

Page 37: ...pped wire via terminal block see sec tion 5 1 for correct wiring Configuration via moni tool software see section 12 1 for address mapping Assembling only by qualified personal authorized by s can con...

Page 38: ...Hz wide range power supply unit Power supply cable outside diameter 5 12 mm single cable wires 1 5 2 5 mm2 min 80 C min 300 VAC Required galvanic isolation of power input 3 0 kV 1 5 kV D 330 230 D 33...

Page 39: ...ax 8 parameters Analog OUT 4 to 20 mA active Resolution 12bit 5 A Accuracy 30 A Max load 500 Ohm Galvanic isolation 1 kV D 315 OUT PROFIBUS blue module address 1 see section 11 5 4 D 315 OUT SDI12 see...

Page 40: ...ot to be used Slot 2 51 and 52 19 and 20 35 and 36 Slot 3 53 and 54 21 and 22 37 and 38 Slot 4 55 and 56 23 and 24 39 and 40 Slot 5 57 and 58 25 and 26 41 and 42 Slot 6 59 and 60 27 and 28 43 and 44 S...

Page 41: ......

Page 42: ...scan Messtechnik GmbH Brigittagasse 22 24 1200 Vienna Austria Tel 43 0 1 219 73 93 0 Fax 43 0 1 219 73 93 12 office s can at www s can at...

Reviews: