background image

 WARNING

Do not start pump until pump chamber is primed 

with water.

Install inlet water pipes before using pumps and 

unscrew transparent pump cover with wrench to 

one-way valve is called as filter elements); inject 

water to pump chamber; recover filter elements 

4

and pump cover to the original, which is shown as 

Fig.17; pumps may be used after electrified and 

5.Cup (to inject water to pump chamber)
6.One-way valve
7.Filter
8.Pump cover
9.Wrench
Tips:

1.  When  pumps  are  starting  normally,  please 

examine leakage of pipelines once again.

2.  Note:  after  filled  with  water,  pumps  fail  to 

discharge water after five minutes of starting, 

close  electric  pumps  and  reinject  water  or 

examine whether inlet water pipes are leaked or 

not.

3.  Fill pump chamber with water before initial use.

MAINTENANCE MANUAL

Clean strainer mesh  (Fig. 18)

To maintain optimum water flow performance, users 

should  clean  strainer  mesh  components  regularly 

according to water quality. The method to clean is as 

follows:

Strainer mesh is rotated as the direction of arrow in 

Fig.19 to separate one-way valve and strainer mesh; 

clean strainer mesh and one-way valve respectively 

with clean water; assemble strainer mesh and one-way 

valve and install them properly for use.

Temperature lowers 4

o

C or extended outage status

If  there  is  any  risks  of  damage  due  to  frost  or 

freezing, or electric pumps may not be used for 

a  long  time,  please  open  screw  plug  for  water 

drainage  to  discharge  water.  When  pumps  are 

and tighten cover before restart.
Tips

:

1.  In winter, in case of out-of-operation of electric 

pumps or temperature is lower 4

o

C, discharge 

liquid in pipelines and pump chamber to prevent 

frost crack of pumps.

2.  In summer or when temperature is high, keep 

good aeration to prevent electric parts having 

dew, thus leading to failures.

3.  If  electric  pumps  overheat  or  are  abnormal, 

p l e a s e   c u t   o f f   p o w e r   p r o m p t l y   a n d 

examine  according  to  methods  specified  in 

troubleshooting guide

SPECIFICATIONS

Rated Power
Max Head
Max. Suction Lift
Max. Water Flow 
Max. Working Temp
Max. Particle Size 
Cable Length

900W

43m

8m

3,600L/hr

 35ºC

0.5mm

 1.5m

Summary of Contents for RCPP900

Page 1: ...RCPP900 CONSTANT PRESSURE PUMP ...

Page 2: ...m Water inlet 2 Pre Filter 3 25mm Water outlet 4 Drain plug 5 Pump Head 6 LCD Display screen 7 Carry Handle 8 900W Induction motor with thermal overload 9 Spanner 10 Thread seal tape 2 3 6 8 7 1 5 4 9 Components List 10 ...

Page 3: ...DESCRIPTION SET OFF CHECK SET 3 6 CHECK m3 h SET 39 CHECK m SET 15 CHECK m SET Err CHECK SET Err CHECK SET 12 00 CHECK TIME NOW SET 12 00 CHECK TIME ON Fig 1 Fig 5 Fig 3 Fig 7 Fig 2 Fig 6 Fig 4 Fig 8 ...

Page 4: ...DESCRIPTION SET 12 00 CHECK TIME OFF Fig 9 Fig 13 Fig 11 Fig 15 Fig 10 Fig 14 Fig 12 Fig 16 ...

Page 5: ...DESCRIPTION Fig 17 Fig 18 Fig 19 ...

Page 6: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification ...

Page 7: ...e of 5cm from any foreign object Risk of uncontrolled situations when used in ambient temperatures below 0 C 32 F or above 40 C 104 F Keep the product dry clean and free from oil and grease Always use a clean cloth when cleaning Keep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in ...

Page 8: ...ING Use a moist cloth to wipe down the pump housing Allow to dry thoroughly before storing in a dry location that is protected from bad weather conditions CLEANING THE PREFILTER The pump is fitted with a pre filter which will need cleaning at regular intervals or replacing if necessary It is recommended to clean the non return valve at the 1 Remove the pre filter using the supplied filter wrench t...

Page 9: ...ncy checking mode with start stop for 6 times within 2mins and the pump stops running if this frequency lasts for one hour with LCD display Timer function Set NOW time Long press SET key to set HOUR of current time and short press SET key to set MINUTE of current time The LCD displays TIME NOW Press CHECK for to set the HOUR or MINUTE of current time till the time is correct Fig 7 Set ON time Cont...

Page 10: ...to clean is as follows Strainer mesh is rotated as the direction of arrow in Fig 19 to separate one way valve and strainer mesh clean strainer mesh and one way valve respectively with clean water assemble strainer mesh and one way valve and install them properly for use Temperature lowers 4o C or extended outage status If there is any risks of damage due to frost or freezing or electric pumps may ...

Page 11: ...erge bottom valve Leakage of suction pipes Examine joints sealing of all suction pipes Deficiency in pressure Inlet water pipes are too long or have too many elbows Pipe diameter is incorrect please refer to installation instructions page 3 Debris blocks entrance of pipelines strainer mesh or pump chamber Clean pipelines bottom valve or pump chamber and remove foreign debris Pump vibration Pump is...

Page 12: ...tronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Imported by ...