BEFORE INSTALLATION

INSTRUCTIONS

Installation precautions of inlet water pipes (Fig. 10,11)

1.  Do not use soft rubber hose to avoid sucking flat 

during the installation of electric pumps.

2.  Bottom valve is vertical and installed above water 

bottom 30cm to avoid sucking silt.

3.  Joints of inlet water pipes must be sealed and have 

elbows as few as possible, otherwise no water will 

be drawn.

4.  Diameter of inlet water pipes should be at least the 

Examine screw plug for water drainage (Fig. 14)

Before using pumps, examine whether screw plug 

for water drainage has been installed properly or not 

and screw on manually or with tools.

Set inlet water pipes (Fig. 15)

Water pumps are connected with circuits:

Steel wire hose or corrugated pipe (2);

Removable connection nut (3);

Water inlet transfer (4);

Correct operations are as follows: screw water inlet 

transfer to water inlet of pumps, and then screw 

removable connection nut to water inlet transfer; 

meanwhile pay attention to sealing pipelines, to 

ensure correct operation check all connections are 

sealed correctly.

Soft start function:

When pump is powered on, LCD displays “OFF”. (Fig . 1), 

pumps starts running after a short period of 2s and 

Dry running function:

The pump runs 3 Dry Running Cycles consisting 

for 20s after the pump is powered on and the pump 

stops after 3 cycles. LCD screen will  flash and 

display  “Err” & ”water tap” (Fig. 5) Pump can only 

be started after unplugging and plugging in again.

Automatic function:

The pump stops after 10s when the outlet valve is 

closed, and the pump starts when the outlet valves 

opens again.

Leakage protection function:

When water pressure can not reach at the normal 

pressure for long time, the pump will enter into the 

frequency checking mode with start & stop for 6 

times within 2mins and the pump stops running if 

this frequency lasts for one hour with LCD display 

Timer function:

Set NOW time:

 Long press "SET" key to set HOUR

of current time and short press "SET" key to set 

MINUTE of current time. The LCD displays “TIME 

NOW”. Press “CHECK” for “+” to set the HOUR or 

MINUTE of current time till the time is correct. (Fig. 7)

Set ON time:

 Continue last step, short press "SET" 

key to set hour of starting time and press "SET" 

key to set minute of starting time. The LCD displays 

“TIME ON”  and press “CHECK” for “+” to set the 

starting HOUR or MINUTE till the ON time is set. 

(Fig. 8)  

Set OFF time:

 Continue last step, press "SET" key 

to set hour of stopping time and press "SET" key to 

set minute of stopping time. The LCD displays “TIME 

OFF” and press “CHECK” for “+” to set the starting 

HOUR or MINUTE till the OFF time is set. (Fig. 9)

same as that of water inlet to prevent great loss of 

water and influence water property.

5.  Notice water level decline when using, and bottom 

valve should not break the surface of water.

6.  When inlet water pipes are longer than 10m or inlet 

water pipes are lifted more than 4m, inlet water 

pipes diameter must be greater than that of water 

inlet of electric pumps.

7.  For additional protection it is recommended to install 

in line filters

Installation precautions of outlet water pipes (Fig. 12)

Diameter of outlet water pipes should be at least the 

same as that of water outlet to minimize pressure, 

Choice of installation location (Fig. 13)

When installing pumps, inlet pipelines should be 

as short as possible and elbows should be as few 

as possible. Pumps should be placed in the well-

ventilated environment. Pumps may be installed 

outdoor, but they must be covered to prevent rain 

damage and frost.

Set outlet water pipes (Fig. 16)

Installation of outlet water pipes is shown as Fig.16, 

the same as installation of water inlet pipes; pay 

leakage is as follows:

<1> Increase usage cost;

<2> Reduce service life of pumps.

rotation of water pumps.

Prime pump chamber with water (Fig. 17)

running and the LCD display 15m (fig. 4):  “SET” 

represents “+” and “CHECK” represents “-”. When 

setting is done, press “SET “ for a short period will 

return to normal running mode, and LCD display the 

“pump head”(m) or “water flow” (m

3

/hr)

Summary of Contents for RCPP900

Page 1: ...RCPP900 CONSTANT PRESSURE PUMP ...

Page 2: ...m Water inlet 2 Pre Filter 3 25mm Water outlet 4 Drain plug 5 Pump Head 6 LCD Display screen 7 Carry Handle 8 900W Induction motor with thermal overload 9 Spanner 10 Thread seal tape 2 3 6 8 7 1 5 4 9 Components List 10 ...

Page 3: ...DESCRIPTION SET OFF CHECK SET 3 6 CHECK m3 h SET 39 CHECK m SET 15 CHECK m SET Err CHECK SET Err CHECK SET 12 00 CHECK TIME NOW SET 12 00 CHECK TIME ON Fig 1 Fig 5 Fig 3 Fig 7 Fig 2 Fig 6 Fig 4 Fig 8 ...

Page 4: ...DESCRIPTION SET 12 00 CHECK TIME OFF Fig 9 Fig 13 Fig 11 Fig 15 Fig 10 Fig 14 Fig 12 Fig 16 ...

Page 5: ...DESCRIPTION Fig 17 Fig 18 Fig 19 ...

Page 6: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification ...

Page 7: ...e of 5cm from any foreign object Risk of uncontrolled situations when used in ambient temperatures below 0 C 32 F or above 40 C 104 F Keep the product dry clean and free from oil and grease Always use a clean cloth when cleaning Keep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in ...

Page 8: ...ING Use a moist cloth to wipe down the pump housing Allow to dry thoroughly before storing in a dry location that is protected from bad weather conditions CLEANING THE PREFILTER The pump is fitted with a pre filter which will need cleaning at regular intervals or replacing if necessary It is recommended to clean the non return valve at the 1 Remove the pre filter using the supplied filter wrench t...

Page 9: ...ncy checking mode with start stop for 6 times within 2mins and the pump stops running if this frequency lasts for one hour with LCD display Timer function Set NOW time Long press SET key to set HOUR of current time and short press SET key to set MINUTE of current time The LCD displays TIME NOW Press CHECK for to set the HOUR or MINUTE of current time till the time is correct Fig 7 Set ON time Cont...

Page 10: ...to clean is as follows Strainer mesh is rotated as the direction of arrow in Fig 19 to separate one way valve and strainer mesh clean strainer mesh and one way valve respectively with clean water assemble strainer mesh and one way valve and install them properly for use Temperature lowers 4o C or extended outage status If there is any risks of damage due to frost or freezing or electric pumps may ...

Page 11: ...erge bottom valve Leakage of suction pipes Examine joints sealing of all suction pipes Deficiency in pressure Inlet water pipes are too long or have too many elbows Pipe diameter is incorrect please refer to installation instructions page 3 Debris blocks entrance of pipelines strainer mesh or pump chamber Clean pipelines bottom valve or pump chamber and remove foreign debris Pump vibration Pump is...

Page 12: ...tronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Imported by ...