background image

power when installing.

 

Do not install  or operate the water pump in an 

explosive environment or near flammable material.

 

Do not operate the water pump without liquid.

 

Do not run the water pump dry.

2

 WARNING

 WARNING

The water pump together with associated pipework 

operate under pressure. Do not disconnect water 

pump or pipework until internal pressure has been 

released. Failure to do this could result in personal 

injury and damage to property.

Make sure the pump is disconnected from electric 

power  supply  before  performing  maintenance 

procedures.

 

Avoid inserting hands into the inlets/outlets of the 

water pump while it is connected to power.

 

Before using the water pump, always inspect it 

visually. Do not use the pump if it is cracked and/or 

damaged.

 

The water pump has a built-in thermal protection 

overload  switch.  The  water  pump  stops  if  an 

overload occurs. The motor restarts automatically 

after it has cooled down.

 

The pump must not be used when people are in the 

water.

 

Never work or perform maintenance on the pump 

without first making sure it has been disconnected 

from the mains power.

 

Pollution of the liquid could occur due to leakage of 

lubricants.

Important: 

Avoid inserting hands into the mouth of 

the pump if it is connected to the mains. The electrical 

connection must always be made in a dry area. Make 

sure that electrical connections are protected from 

inundations.

Protect the plug and the power cable from heat, oil or 

sharp edges.

MAINTENANCE

CLEANING THE PUMP HOUSING

Use a moist cloth to wipe down the pump housing. 

Allow to dry thoroughly before storing in a dry location 

that is protected from bad weather conditions.

CLEANING THE PREFILTER

The pump is fitted with a pre-filter which will need 

cleaning at regular intervals or replacing if necessary. 

It is recommended to clean the non-return valve at the 

1.  Remove the pre-filter using the supplied filter wrench 

to loosen the screw by turning in a anti-clockwise 

direction.

2.  Unscrew the non-return valve from the bottom of the 

pre-filter.

3.  Tap the filter and non-return valve on a flat surface 

gently. For stubborn dirt, simply rinse with water.

NOTE: 

Do not use abrasive cleaning agents to clean

1.  Once clean re-assemble the pre-filter and non-return 

valve.

2.  Screw the pre-filter onto the pump and tighten with 

the supplied filter wrench.

INTENDED USE

SYMBOLS DEFINITION ON THE PRODUCT

LCD OPERATION MODE

The constant pressure pump is intended to be used 

only  by  adults  who  have  read  and  understood  the 

instructions and warnings in this manual, and can be 

considered responsible for their actions.

The product is intended for drawing water for domestic 

use, water from wells, increase pressure for pipelines 

sinks, water basins etc.  

1. 

   .

F

F

O

 

s

y

a

l

p

s

i

d

 

D

C

L

 ,

n

o

 

d

e

r

e

w

o

p

 

s

p

m

u

p

 

n

e

h

W

(Fig. 1)

2.  Pumps starts running after a short period of 2s and 

LCD displays “ water flow rate” and “water tap” 

symbol (Fig. 2).

3.  Press “SET” for switch on and switch off the pump.
4.  When pump is running, press ‘CHECK” for short 

period to switch over the “pump head”(m)(Fig. 3) or 

“water flow” (m

3

/hr) (Fig. 2) when pump is running . 

5.  When pump is running, press ‘CHECK” for long 

period to set the water pressure, the pump stops 

Summary of Contents for RCPP900

Page 1: ...RCPP900 CONSTANT PRESSURE PUMP ...

Page 2: ...m Water inlet 2 Pre Filter 3 25mm Water outlet 4 Drain plug 5 Pump Head 6 LCD Display screen 7 Carry Handle 8 900W Induction motor with thermal overload 9 Spanner 10 Thread seal tape 2 3 6 8 7 1 5 4 9 Components List 10 ...

Page 3: ...DESCRIPTION SET OFF CHECK SET 3 6 CHECK m3 h SET 39 CHECK m SET 15 CHECK m SET Err CHECK SET Err CHECK SET 12 00 CHECK TIME NOW SET 12 00 CHECK TIME ON Fig 1 Fig 5 Fig 3 Fig 7 Fig 2 Fig 6 Fig 4 Fig 8 ...

Page 4: ...DESCRIPTION SET 12 00 CHECK TIME OFF Fig 9 Fig 13 Fig 11 Fig 15 Fig 10 Fig 14 Fig 12 Fig 16 ...

Page 5: ...DESCRIPTION Fig 17 Fig 18 Fig 19 ...

Page 6: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification ...

Page 7: ...e of 5cm from any foreign object Risk of uncontrolled situations when used in ambient temperatures below 0 C 32 F or above 40 C 104 F Keep the product dry clean and free from oil and grease Always use a clean cloth when cleaning Keep handles and grasping surfaces dry clean and free from oil and grease Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in ...

Page 8: ...ING Use a moist cloth to wipe down the pump housing Allow to dry thoroughly before storing in a dry location that is protected from bad weather conditions CLEANING THE PREFILTER The pump is fitted with a pre filter which will need cleaning at regular intervals or replacing if necessary It is recommended to clean the non return valve at the 1 Remove the pre filter using the supplied filter wrench t...

Page 9: ...ncy checking mode with start stop for 6 times within 2mins and the pump stops running if this frequency lasts for one hour with LCD display Timer function Set NOW time Long press SET key to set HOUR of current time and short press SET key to set MINUTE of current time The LCD displays TIME NOW Press CHECK for to set the HOUR or MINUTE of current time till the time is correct Fig 7 Set ON time Cont...

Page 10: ...to clean is as follows Strainer mesh is rotated as the direction of arrow in Fig 19 to separate one way valve and strainer mesh clean strainer mesh and one way valve respectively with clean water assemble strainer mesh and one way valve and install them properly for use Temperature lowers 4o C or extended outage status If there is any risks of damage due to frost or freezing or electric pumps may ...

Page 11: ...erge bottom valve Leakage of suction pipes Examine joints sealing of all suction pipes Deficiency in pressure Inlet water pipes are too long or have too many elbows Pipe diameter is incorrect please refer to installation instructions page 3 Debris blocks entrance of pipelines strainer mesh or pump chamber Clean pipelines bottom valve or pump chamber and remove foreign debris Pump vibration Pump is...

Page 12: ...tronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia TechtronicIndustriesN Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand Imported by ...