background image

8

MAINTENANCE

WARNING.

Do not operate the meter

until the battery compartment cover is in

place and fastened

GENERAL MAINTENANCE

This instrument is designed to provide years of

dependable service, if the following care

instructions are performed:
Keep the moisture meter dry and free from dust.
Use and store the moisture meter in nominal

temperature conditions. Temperature extremes can

shorten the life of the electronic parts and distort or

melt plastic parts.

Handle the moisture meter carefully and avoid

shock and vibration. Dropping the meter may

damage the electronic parts or the case.
Keep the moisture meter clean. Wipe the case

occasionally with a damp cloth. DO NOT use

chemicals, cleaning solvents, or detergents.
Use only fresh batteries of the correct type.

Remove old or weak batteries so they do not leak

and damage the unit.
If the moisture meter is to be stored for long

periods, the batteries should be stored separately

to prevent damage to the unit.

RECYCLING AND DISPOSAL

GENERAL MAINTENANCE

Recycle unwanted materials instead of disposing of

them as waste. All tools, hoses and packaging

should be sorted, taken to the local recycling centre

and disposed of in an environmentally safe way.
Recycle rather than dispose of unwanted material

in landfill whenever possible. The machine must be

delivered in rigid packaging to avoid damage

during transportation. The packaging and the

machine itself are manufactured from recyclable

materials and should be disposed of accordingly.
Only dispose of electrical/electronic/battery terms

in separate collection schemes, which cater for the

recovery and recycling of materials contained

within. Your cooperation is vital to ensure the

success of these schemes and for the protection of

the environment.
Recycle packaging where facilities exist.

This symbol is known as the Crossed

out Wheelie Bin Symbol. When this

symbol is marked on a product or

battery, it means that it should not be

disposed of with your general

household waste. Some chemicals

contained within electrical/electronic products or

batteries can be harmful to health.

SERVICE

Now that you have purchased your tool, should a need ever exist of repair or service, simply contact your

nearest Ryobi Authorised Service Centre or other qualified service organistion. Be sure to provide all

pertinent facts when you call or visit.

Summary of Contents for MM-210

Page 1: ......

Page 2: ...able service SPECIFICATIONS Screen display area size 35 x 29 5mm Operating temperature 0 40ºC Operating humidity 85 relative humidity maximum Storage temperature 20 70ºC Battery 2 x 1 5V AAA batteries Rated current 50mA Probe measuring range accuracy Wood 5 50 2 Building materials 1 5 33 2 Temperature 0 40ºC 2ºC 32 99ºF 4ºF Scanning measuring range accuracy Softwood 0 53 4 Hardwood 0 35 4 Maximum ...

Page 3: ...ng WARNING To reduce the risk of injury the user must read and understand the operator s manual WARNING Do not attempt to operate this tool until you have read thoroughly and understood completely all instructions safety rules etc contained in this manual Failure to comply may result in accidents involving fire electric shock or serious personal injury Save operator s manual and review frequently ...

Page 4: ...3 DESCRIPTION 2 1 Probes with protective covers 2 Probe lid 3 Battery compartment rear of unit 4 Scroll down button 5 Hold button 6 Scroll up button 7 On Off button 8 LCD detail on page 4 3 8 1 5 4 6 7 ...

Page 5: ...Wood humidity probe mode 4 Low battery indicator 5 Humidity value locked symbol 6 Probe measuring mode icon 7 Celcius Fahrenheit 8 Percentage unit 9 Measurement range 10 Numerical reading 11 Hardwood scanning mode 12 Softwood scanning mode 13 Masonry scanning mode 14 Drywall scanning mode 7 12 1 8 10 9 5 11 13 14 6 2 3 ...

Page 6: ...eter and fit according to the symbols inside the battery compartment See Fig 1 WARNING Do not attempt to modify this product Any such alteration or modification is misuse and could result in a hazardous condition leading to possible serious personal injury BATTERY REPLACEMENT If the instrument does not switch on or the battery symbol has no bars replace the batteries as previously stated above BAT...

Page 7: ...hing scanning icon The default setting for scanning mode is always DRYWALL Fig 3 There are 4 different scanning modes that can be chosen DRYWALL MASONRY SOFTWOOD HARDWOOD Select the corresponding scanning measurement mode according to the properties of the object to be tested For example chooses MASONRY mode for a concrete wall by pressing the Scroll Up and Scroll Down buttons Fig 4 5 Place the se...

Page 8: ...SURING MODE The measuring building materials operation is the same as measuring wood Use the Scroll Up and Scroll Down buttons to scroll to the BLDG probe measuring mode screen Fig 9 Insert the probes into the building material The moisture value of the building material will be displayed on the screen If you wish to lock the measurement value on the screen press the HOLD button The value locked s...

Page 9: ...ste All tools hoses and packaging should be sorted taken to the local recycling centre and disposed of in an environmentally safe way Recycle rather than dispose of unwanted material in landfill whenever possible The machine must be delivered in rigid packaging to avoid damage during transportation The packaging and the machine itself are manufactured from recyclable materials and should be dispos...

Page 10: ...tuation that may result in property damage Safety Alert Symbol Indicates danger warning or caution It means attention Your safety is involved Recycle Symbol Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice CE Marking Conforms to relevant safety standards Read Your Operator...

Page 11: ...10 NOTES ...

Page 12: ...11 NOTES ...

Reviews: