Digalox DPM72-MPPV

Instruction manual (Rev-2020-09)

Graphical panel meter with RGB backlight for analogue signal 2 × 0/2 - 10 V

Package contents:

Panel meter Digalox DPM72-MPPV, mounting bracket,
5 jumpers, 2 instruction manuals (EN + DE)

1. Safety instructions

Read   instruction   manual   carefully   before   operating   the   device!   Keep   for   later
reference.

Mounting and installation must be carried out by suitably qualified and competent
persons only.

When working on the device hazardous voltages must not be connected to
the   device!   The   terminals   J1-J12   are   not   isolated   from   the   measuring
circuit.

The device must not be used as the only protective device or protective
shutdown.

The device is not intended to protect persons or facilities against harm. Specific
devices must be used to guarantee safety (protection relays, cut-off switches,
etc.).

When connecting switches to the terminals J1-J6, only switches must be used
whose isolation voltage is at least twice the maximum occurring measurement
voltage. For example, when measuring 30 V DC switches must be isolated for at
least 60 V.

Do not open the housing!

Do not use the device in the presence of explosive or flammable substances!

All cables carrying hazardous voltages must be secured with external separators.

2. Meaning of symbols

General warning sign
(Attention, observe the documentation!)

Warning of an electrical hazard

-----

 1 / 8 

-----

Summary of Contents for Digalox DPM72-MPPV

Page 1: ...t The device must not be used as the only protective device or protective shutdown The device is not intended to protect persons or facilities against harm Specific devices must be used to guarantee safety protection relays cut off switches etc When connecting switches to the terminals J1 J6 only switches must be used whose isolation voltage is at least twice the maximum occurring measurement volt...

Page 2: ... timespan of 36 seconds up to 14 days The timebase as well as the display of the measuring history can be activated by an external switch The measured values remain stored as long as the device is supplied with voltage The following parameters can be adjusted using the configuration software Digalox Manager scale endpoint scale caption display style pointer tachometer bar graph and more splash ima...

Page 3: ... 2 1 4 5 Back 1 2 optocoupler switch outputs 2 Jumper pins J1 J12 for activating switching of graphical historic data display min max display auto scaling measurement mode 3 Supply voltage input 4 Interface USB XBEE RS485 5 Measurement inputs 6 Mounting Carefully insert the device into the panel cut out Insert the mounting bracket from the back and push towards the panel until the device sits tigh...

Page 4: ...e e g active sensor or sensor with voltage supply 10 V analogue signal U2low U2high max 30 V U1high U1low 0 V 10 V 2 10 V analogue signal U2low U2high max 30 V U1high U1low 0 V 10 V max 30 V 0 V 10 V WARNING The device may only be operated in one of the connection options shown above 4 8 ...

Page 5: ...nager software and connect it to the device Settings can then be made on the various tabs and saved in the device Please note that the measurement mode selected in Digalox Manager is displayed only until the power supply of the DPM72 is interrupted In further operation the device always shows the first measurement mode or the one that is selected by the jumpers J4 J6 see table Measurement mode in ...

Page 6: ...1 interval 2 sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next setting In order to save the setting permanently the software Digalox Manager has to be used J2 Min Max display The display shows the maximum and minimum values recorded since the last reset The values can be reset by opening and closing co...

Page 7: ...update 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 internal memory locations Alarm outputs 2 optocoupler outputs max 30 V DC 50 mA Permissible voltage between supply and measuring inputs 50 V AC 75 V DC Connections measuring inputs Wire gauge Wire strip length Pitch 0 2 3 3 mm 24 to 12 AWG 7 8 mm 7 62 mm Connections supply alarm outputs and RS485 Wire gauge Wire st...

Page 8: ... information TDE Instruments GmbH Gewerbestraße 8 D 71144 Steinenbronn Phone 49 7157 20801 E Mail info tde instruments de Internet www tde instruments de www digalox com 8 8 56 3 83 5 72 0 72 0 77 5 18 6 27 0 9 6 2 9 73 5 72 0 55 3 63 0 72 0 2 9 35 9 67 5 83 5 Panel cut out 68 0 68 0 86 9 58 2 36 7 ...

Reviews: