background image

5

ACCURACY CHECK OF THE MEASURING TOOL 

The accuracy of the measuring tool can be checked as 

follows: 

.

  Select a permanently unchangeable measuring section 

with a lengh of approx. 3 to 10 metres;its length must 

be precisely known (e.g. the width of a room or a door 

opening).The measuring distance must be indoors;the 

target surface for the measurement must be smooth and 

reflect well. 

.

  Measure the distance 10 times after another. The 

deviation of the individual measurements from the 

mean value must not exceed ±2mm(max.).Log the 

measurements,so that you can compare their accuracy at 

a later point of time. 

MAINTENANCE 

This laser distance measure has been designed to be 

a low-maintenance tool. However, in order to maintain 

its performance, you must always follow these simple 

directions. 

 

1. Always 

handle the tool with care. Treat it as an optical 

device, such as a camera or binoculars. 

 

2. Avoid 

exposing the tool to shock, continuous vibration or 

extreme hot or cold temperature. 

 3

. Always

 store the tool indoors. When not in use, 

ALWAYS

 

store the tool in its protective case. 

 

4. Always

 Keep the tool free of dust and liquids. Use only a 

clean, soft cloth for cleaning. If necessary, slightly moisten 

the cloths with pure alcohol or a little water. 

  5.  Do not touch the lens with your fingers. 

 6. Check the batteries regularly to avoid deterioration. 

ALWAYS

 remove the batteries from the tool, if it is not 

going to be used for an extended period of time. 

  7. Replace the batteries when the battery icon is continuously 

empty displayed on the LCD. 

 8. Do not

 disassemble the laser measuring tool; this will 

expose the user to hazardous radiation exposure. 

 

9.  Do not

 attempt to change any part of the laser lens. 

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. 