BATTERY PROTECTION FEATURES

Ryobi lithium-ion batteries are designed with features that 

protect the lithium-ion cells and maximize battery life.
If the product stops during use, the battery needs to be 

recharged.

TO INSTALL/REMOVE BATTERY PACK
See figure 2

 WARNING

Always remove battery pack from your tool when you 

are assembling parts, making adjustments, cleaning, or 

when not in use. Removing battery pack will prevent 

accidental starting that could cause serious personal 

injury.

To install:

 

„

Place the battery pack in the tool. Align the raised rib 

on the battery pack with groove in the battery port.

 

„

Make sure the latches on each side of the battery pack 

snap in place and that the battery pack is secured in 

the tool before beginning operation.

To remove:

Depress the latches on both sides of the battery pack to 

release the battery pack and remove it from the tool.

 WARNING

Improperly attached hoses or accessories can become 

detached under pressure and cause serious injury. 

Possible air leaks can cause faulty pressure readings. 

Make sure all connections are tightly secured.

DUAL HOSES

The inflator has two hoses for two types of inflation. The 

high pressure hose is for inflating high pressure items like 

tires and sports balls. The low pressure hose is designed 

for inflating or deflating low pressure, high volume items 

like air rafts, mattresses, and floats.
NOTE: Pressure gauge and preset features are relative 

only to high pressure hose applications.

POWER SWITCH

Place the power switch in the (I) position to turn on the 

low pressure pump or the (II) position to turn on the high 

pressure pump. Place the switch in the (O) or center 

position to stop all pump operations.

DIGITAL GAUGE
See figure 3

The digital gauge is multifunctional serving as a pressure 

gauge, monitoring the amount of pressure being applied 

to  the  item  being  inflated,  and  changing  air  pressure 

measurement units from PSI to BAR to kPa.

 

„

Press the mode button to turn on the digital gauge.
NOTE: Make sure digital gauge is set at 0 before use. 

If gauge reads “Err” or needs resetting, press and hold 

the mode button for 4-7 seconds.

 

„

Select desired measurement unit (PSI, BAR, kPa) by 

pressing and releasing the mode button. Press once 

for PSI, twice for BAR, and three times for kPa.
NOTE: After preset pressure has been set, pressure 

setting stays in the gauge memory for 180 seconds. 

To recall the previous pressure setting for up to 180 

seconds after inflation, press the (+) or (-) button. To 

reset preset pressure, press and hold the mode button.

 

„

Position air chuck clamp in the unlock position 

perpendicular to the high pressure air hose.

 

„

Place air chuck on valve stem.

 

„

Push air chuck down so that the threaded section of 

the valve stem is inside the air chuck.

 

„

Clamp the end of the air chuck down onto the valve 

stem by pressing air chuck clamp down until it stops or 

is parallel with the high pressure air hose.

NOTE: The pressure readout on the gauge while inflating 

is  a  measurement  of  the  fluctuating  pressure  between 

the item and the high pressure hose. To get an accurate 

reading,  stop  inflating  and  follow  above  instructions  for 

reading the air pressure.

AUTOMATIC SHUTOFF

The digital gauge will remain on for up to five minutes. To 

manually shut off, press and hold the mode button until the 

light turns off then release the button.

INFLATING WITH THE LOW PRESSURE HOSE
See figure 4

The  low  pressure  hose  is  used  to  inflate  low  pressure 

items, such as air mattresses, pools, and floats.
NOTE: A pinch valve adaptor comes as part of the small 

inflatable nozzle assembly that is attached to the end of 

the low pressure hose. The pinch valve adaptor is used 

for items that have a smaller air opening or pinch valve. 

Insert pinch valve adaptor into pinch valve, ensuring that 

the tip of the adaptor is inserted past the inner “flap” inside 

the valve. When inflating, ensure that the tip is not blocked 

during inflation.

 

„

Align the slots in the hose with the pins on the sides 

of the inflator.

Summary of Contents for CIT1800G

Page 1: ...CIT1800G 18 VOLT INFLATOR DEFLATOR OWNER S OPERATING MANUAL ORIGINAL INSTRUCTIONS ...

Page 2: ...storage 8 Inflator 9 Deflator 10 Pin 11 Battery pack 12 Latches 13 Depress latches to release battery pack 14 Button 15 Mode button 16 Button 17 Valve stem 18 Air chuck 19 To lock 20 To unlock 21 Air chuck clamp 22 Presta valve 23 Presta valve adaptor 24 Locking nut 25 Tapered adaptor 26 Sport ball needle 27 To tighten 28 To loosen 29 Presta valve stem 30 Hose wrap Fig 1 Fig 2 Fig 3 ...

Page 3: ...2 1 9 17 18 5 19 20 21 22 18 5 19 20 21 23 24 18 25 19 20 23 26 27 28 29 24 Fig 4 Fig 6 Fig 8 Fig 5 Fig 7 Fig 9 ...

Page 4: ...30 7 30 Fig 10 Fig 11 ...

Page 5: ...Important It is essential that you read the instructions in this manual before operating this machine Subject to technical modifications ...

Page 6: ...l injury Use personal protective equipment Always wear eye protection Protective equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Prevent unintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power too...

Page 7: ... the system slowly Dust and debris may be harmful Never point any inflator toward yourself or others Do not exceed the pressure rating of any component in the system Protect material lines and air lines from damage or puncture Keep hose and power cord away from sharp objects chemical spills oil solvents and wet floors Do not preset inflator to result in output pressure greater than marked maximum ...

Page 8: ...ot recommended by the manufacturer of this tool The use of attachments or accessories not recommended can result in serious personal injury WARNING Do not leave items to be inflated unattended while inflator is in use These items can burst and could cause serious injury CAUTION The inflator is not designed for continuous use For every ten minutes of inflator use ten minutes of cool down time are r...

Page 9: ...ssure measurement units from PSI to BAR to kPa Press the mode button to turn on the digital gauge NOTE Make sure digital gauge is set at 0 before use If gauge reads Err or needs resetting press and hold the mode button for 4 7 seconds Select desired measurement unit PSI BAR kPa by pressing and releasing the mode button Press once for PSI twice for BAR and three times for kPa NOTE After preset pres...

Page 10: ...ESSURE HOSE AND ACCESSORIES See figures 7 9 The high pressure hose can be used with the provided adaptors to inflate a variety of items To install accessory insert adaptor or needle into air chuck and push air chuck clamp down until it locks into place Inflate to desired pressure Remove accessory by lifting air chuck clamp up and pulling the adaptor or needle from air chuck INFLATING MANUALLY FOR ...

Page 11: ...avoid serious personal injury always remove the battery pack from the tool when cleaning or performing any maintenance Avoid using solvents when cleaning plastic parts Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use Use clean cloths to remove dirt dust oil grease etc WARNING Do not at any time let brake fluids gasoline petroleum bas...

Page 12: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand ...

Reviews: