background image

8

English

Compatible battery pack 

(not included)

Compatible charger 

(not included)

Lithium-Ion

BPL-1820

BPL-1815

BPL18202PK

RB18L13

RB18L15

RB18L26

RB18L40

RB18LL40

BCL1418

BCS618

BCL14181H

BCL14183H

BCL1418IV*

Nickel 

Cadmium

ABP1801G

ABP1802G

ABP-1813

ABP-1815

RB18N15

BCL1418

BCS618

ACR1800G

260022029

BCL14181H

BCL14183H

BCL1418IV*

*

 for vehicles with 12V DC outlets

OPERATION

 WARNING

Do not use this product if it is not completely assembled 

or if any parts appear to be missing or damaged. Use of 

a product that is not properly and completely assembled 

could result in serious personal injury.

 WARNING

Do  not  attempt  to  modify  this  inflator  or  create 

accessories not recommended for use with this inflator. 

Any such alteration or modification is misuse and could 

result in a hazardous condition leading to possible 

serious personal injury.

 WARNING

Do not allow familiarity with this product to make you 

careless. Remember that a careless fraction of a 

second is sufficient to inflict serious injury.

 WARNING

Always wear eye protection with side shields marked to 

comply with ANSI Z87.1. Failure to do so could result 

in objects being thrown into your eyes resulting in 

possible serious injury.

 WARNING

Do not use any attachments or accessories not 

recommended by the manufacturer of this tool. The use 

of attachments or accessories not recommended can 

result in serious personal injury.

 WARNING

Do  not  leave  items  to  be  inflated  unattended  while 

inflator  is  in  use.  These  items  can  burst  and  could 

cause serious injury.

 CAUTION

The  inflator  is  not  designed  for  continuous  use.  For 

every ten minutes of inflator use, ten minutes of cool 

down time are required.

 WARNING

Since the pressure gauge is not calibrated, and is 

therefore not binding for exact values, tire pressure 

must be checked using a reliable measuring device 

before driving a vehicle with vehicle tires inflated with 

the  inflator.  Driving  a  vehicle  with  improperly  inflated 

tires could result in serious injury.

 CAUTION

The inflator is capable of inflating to 150 PSI, 10.3 BAR, 

or  1030  kPa.  To  avoid  over  inflation,  carefully  follow 

instructions  on  items  to  be  inflated.  To  avoid  product 

damage, never exceed recommended pressures.

APPLICATIONS

You may use this tool for the purposes listed below.

 

„

Inflating high pressure items like motorcycle, car, and 

bicycle tires.

 

„

Inflating and deflating low pressure items like air 

mattresses, rafts and floats.

NOTE: The tool is not designed for commercial application.
This product will accept Ryobi One+ 18 V lithium-ion 

battery packs and Ryobi One+ 18 V nickel-cadmium 

battery packs.
For complete charging instructions, refer to the Operator’s 

Manuals for your Ryobi One+ battery pack and charger 

models.

Summary of Contents for CIT1800G

Page 1: ...CIT1800G 18 VOLT INFLATOR DEFLATOR OWNER S OPERATING MANUAL ORIGINAL INSTRUCTIONS ...

Page 2: ...storage 8 Inflator 9 Deflator 10 Pin 11 Battery pack 12 Latches 13 Depress latches to release battery pack 14 Button 15 Mode button 16 Button 17 Valve stem 18 Air chuck 19 To lock 20 To unlock 21 Air chuck clamp 22 Presta valve 23 Presta valve adaptor 24 Locking nut 25 Tapered adaptor 26 Sport ball needle 27 To tighten 28 To loosen 29 Presta valve stem 30 Hose wrap Fig 1 Fig 2 Fig 3 ...

Page 3: ...2 1 9 17 18 5 19 20 21 22 18 5 19 20 21 23 24 18 25 19 20 23 26 27 28 29 24 Fig 4 Fig 6 Fig 8 Fig 5 Fig 7 Fig 9 ...

Page 4: ...30 7 30 Fig 10 Fig 11 ...

Page 5: ...Important It is essential that you read the instructions in this manual before operating this machine Subject to technical modifications ...

Page 6: ...l injury Use personal protective equipment Always wear eye protection Protective equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Prevent unintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power too...

Page 7: ... the system slowly Dust and debris may be harmful Never point any inflator toward yourself or others Do not exceed the pressure rating of any component in the system Protect material lines and air lines from damage or puncture Keep hose and power cord away from sharp objects chemical spills oil solvents and wet floors Do not preset inflator to result in output pressure greater than marked maximum ...

Page 8: ...ot recommended by the manufacturer of this tool The use of attachments or accessories not recommended can result in serious personal injury WARNING Do not leave items to be inflated unattended while inflator is in use These items can burst and could cause serious injury CAUTION The inflator is not designed for continuous use For every ten minutes of inflator use ten minutes of cool down time are r...

Page 9: ...ssure measurement units from PSI to BAR to kPa Press the mode button to turn on the digital gauge NOTE Make sure digital gauge is set at 0 before use If gauge reads Err or needs resetting press and hold the mode button for 4 7 seconds Select desired measurement unit PSI BAR kPa by pressing and releasing the mode button Press once for PSI twice for BAR and three times for kPa NOTE After preset pres...

Page 10: ...ESSURE HOSE AND ACCESSORIES See figures 7 9 The high pressure hose can be used with the provided adaptors to inflate a variety of items To install accessory insert adaptor or needle into air chuck and push air chuck clamp down until it locks into place Inflate to desired pressure Remove accessory by lifting air chuck clamp up and pulling the adaptor or needle from air chuck INFLATING MANUALLY FOR ...

Page 11: ...avoid serious personal injury always remove the battery pack from the tool when cleaning or performing any maintenance Avoid using solvents when cleaning plastic parts Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use Use clean cloths to remove dirt dust oil grease etc WARNING Do not at any time let brake fluids gasoline petroleum bas...

Page 12: ...Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster VIC 3108 Australia Techtronic Industries New Zealand Ltd 18 26 Amelia Earhart Avenue Mangere Auckland 2022 New Zealand ...