Incubator
User Manual A
Page 1: ...CO2 Incubator User Manual A...
Page 2: ...emark or mark in this instruction manual are only for editing purposes without other purposes the rights belong to their respective rights owners Statement RWD reserves the right to modify the content...
Page 3: ...structure 7 3 1 Incubator Installation 7 3 1 1 Precautions before Installiation 7 3 1 2 Preliminary cleaning 7 3 1 3 Install the inner cover assembly 7 3 1 4 Install vertical plates and ejector rob as...
Page 4: ...sterilization 21 4 6 Sensor calibration 23 4 7 General 24 4 8 Other operations 24 4 9 Alarm and prompt message 26 5 Maintenance 29 5 1 Preventive maintenance 29 5 2 Clean the inside of incubator 30 5...
Page 5: ...ator below CO2 Incubator D180 P 1 2 Safety Before operating the system please read the 2 System Safety section carefully to avoid damages to laboratory animals operators and the system during applicat...
Page 6: ...e of heating sterilization The microprocessor control system is used to monitor the whole process of high temperature sterilization in real time and also display the status information in different st...
Page 7: ...y s 1 8 Product list Attachment Accessory name Quantity Application description Standard Host 1 Body of CO2 Incubator Standard Vertical plate of CO2 Incubator provided with 6 button holes 2 For suppor...
Page 8: ...he following safety symbols and general marks may be used in the User Manual and on the equipment If you have any question or suggestion regarding safety please contact RWD for after sales support To...
Page 9: ...a reliable grounding device The responsibility for equipment failure arising from any improper cleaning maintenance and operation of the equipment should be borne by the user If the equipment host is...
Page 10: ...should between 1 2 atmospheres 1Standard atmosphere 101 325kPa 1bar 14 5Psi If the CO2 Incubator is overheated at 160 C the internal temperature protector will cut off the heating power In this case...
Page 11: ...he CO2 Incubator along both sides of its base instead of lifting it from its front and rear sides 3 1 2 Preliminary cleaning 1 Any plastic film observed on the horizontal shelves vertical plates and e...
Page 12: ...tallation direction of vertical plates need not to be distinguished any one of them can be installed on the opposite side by rotated During the installation process tilt vertical plates slightly so th...
Page 13: ...the opposite side of the ejector robs Spring will then be inserted into place after a cracking sound Slide the end covers into ejector rods from above the springs Insert one end of ejector rod into t...
Page 14: ...HEPA filter is installed 3 1 8 Adjust the equipment level Place a bubble level on the horizontal shelf to check whether the equipment is level Operation method Rotate the hex nut of bubble level coun...
Page 15: ...ge Tap water is not recommended because it may contain chlorine and erode stainless steel Tap water may also contain large amounts of minerals that form scale in the humidity pan High purity water or...
Page 16: ...intained between 1 0bar and 1 5bar to ensure the proper operation of the CO2 control system When the pressure in the CO2 cylinder falls The CO2 single stage pressure regulator cannot maintain the pres...
Page 17: ...out the communication interface and front door heating film terminal at the positions shown below 5 Use a cross screwdriver to remove the screws on the small cover and take out the wire plug and wire...
Page 18: ...e to help lift the equipment Lift the CO2 Incubator along both sides of its bas Four stacking racks are included in the accessory kit for each incubator 1 Stack two incubators and tighten the four sup...
Page 19: ...Stacking rack Supporting feet...
Page 20: ...3 2 Product show and ports introduction Product real shot display 1 2 3 4 5 6 7 8 9...
Page 21: ...interface Export data information 4 CO2 inlet CO2 cylinder connection port 5 CO2 sampling port CO2 sampling within incubator 6 Cooling pan Heat dissipation of equipment 7 220V Power outlet Power outle...
Page 22: ...rt the equipment and enter the main operation interface as shown below The parameter display area on main interface includes TEMP temperature CO2 CO2 concentration PCO2 CO2 pressure and RH relative hu...
Page 23: ...ture The default delivery temperature is 37 C b The CO2 setting range of incubator is 0 0 20 0 The default value of delivered CO2 is 0 0 Click the Default key to restore to the factory set The tempera...
Page 24: ...meters Description of setting range Temperature alarm threshold Upper limit T 0 1 T 5 0 Lower limit T 0 1 T 5 0 CO2 concentration alarm threshold Upper limit C 0 1 C 1 0 Lower limit C 0 1 C 1 0 Lower...
Page 25: ...stains traces of dried materials and eliminate odor There may be odor during the sterilization cycle which is a normal phenomenon The sterilization cycle does not apply to other projects or instrumen...
Page 26: ...r exposure to high temperature for a period of time which is a normal phenomenon Warning The inner surface of the incubator will be heated to 140 C during the sterilization cycle During this process t...
Page 27: ...enu interface to enter the following interface External auxiliary calibration of temperature probe The chamber temperature must be stable before calibration Place the prepared temperature calibration...
Page 28: ...o be input during the operation of Para SET and ALM SET interfaces to prevent the misoperation of user Click the Enable to get a pop up window such as the following left figure correctly enter the pas...
Page 29: ...prompts ALM Log The alarm record interface is shown as below and the user can export the alarm record by clicking Export Event The operation log interface is shown as below and the user can also expo...
Page 30: ...the after sales staff Temperature above alarm limit Actual temperature of inner cavity the upper limit of set temperature alarm threshold 1 Adjust the upper alarm limit 2 Check whether the ambient tem...
Page 31: ...tive humidity below alarm limit The current humidity is lower than the lower limit of humidity alarm 1 Fill the humidity pan with water Humidity sensor error MCU have no communication with humidity se...
Page 32: ...nel failed 1 Contact the after sales staff 006 Motor error please check if anything stuck in HEPA filter or contact after sales personnel Motor fault 1 motor plugging check whether there is any foreig...
Page 33: ...ner surface of incubator Replace the access port filter Replace the CO2 filter Replace HEPA Perform sterilization cycle as needed Warning If the equipment is running turn it off and disconnect the pow...
Page 34: ...eaned The cabinet and doors must be rinsed with sterile water until all disinfectants are cleaned Spray 70 alcohol after rinsing the incubator chamber 5 Install the vertical plates inner door gasket a...
Page 35: ...HEPA filter screen pops up on the message display please replace the HEPA filter in time The user can set a fixed time for the replacement prompt message of HEPA filter screen The prompt period can be...
Page 36: ...esidual CO2 gas 2 CO2 Sensor zero deviation 1 Close the main valve of CO2 cylinder open the incubator door and observe the CO2 display value after around 3 minutes 2 Contact after sales staff of RWD L...
Page 37: ...ance and parts replacement Any damage caused by improper use or over range use is not covered by the warranty If repair or replacement of parts is required the cost will be borne by the user If the re...
Page 38: ...San Diego CA 92121 USA Add Room201 Robeta Building No 11 High Tech North 4th Road Nanshan District Shenzhen City Guangdong Province 518057 China Tel 001 858 900 6602 86 755 86111286 After sales Servic...