background image

3

Russound ALT-126R Installation Manual

PRODUCT OVERVIEW

Introduction

The ALT-126R UltraMatch™ Volume Control is a wall-mounted standard or Decora® style stereo 

speaker-level 12-step attenuator. It connects between the speaker outputs of an amplifi er/receiver 
and a pair (or multiple pairs) of speakers. The ALT-126R adjusts volume level by attenuating the 
amplifi er signal output of the ALT-126R to the speakers. It is manufactured using a high-quality 
autoformer design for long life, excellent frequency response, no heat build-up, and maximum 
power transfer from the amplifi er to the speakers.

The UltraMatch™ designation means the ALT-126R can match the minimum output impedance of 

the amplifi er/receiver, in addition to adjusting volume. It eliminates the need for a speaker selector 
or other impedance matching equipment. When the impedance matching switch is in 1X position 
the volume control can be used as a standard control. The 2X, 4X, and 8X settings allow it to be 
used as an UltraMatch™ control.

Considerations

Amplifi er power rating

 - Make sure the amplifi er has 20 watts per channel for each pair of 

speakers to be connected.

How many ALT-126R

 - An UltraMatch™ volume control should be used for each pair of speakers 

(however, up to 2 pairs of speakers can be used on each control).

Speaker rating

 - A minimum 4-ohm speaker load can be connected to the Output of each 

UltraMatch™ volume control.

Impedance matching switch

 - Each ALT-126R in the system must have the impedance matching 

switch positioned correctly (1X, 2X, etc.). Switch must be set BEFORE the ALT-126R is installed.

Installation location

 - Typical locations for ALT-126R installation include proximity to other wall 

controls, near a desk or next to entrances.

Proper impedance matching switch position for UltraMatch™ Impedance Matching

 - ALT-126R 

impedance matching switch position must be choosen to correctly multiply the impedance of the 
system to a level that equals or exceeds the minimum impedance of the amplifi er.

By determining the impedance capability of the amplifi er with a few simple calculations, you can 

determine the number of speakers the system can safely operate. The impedance matching switch 
position can then be determined by using the charts on the next pages.

ALT-126R_Manual.indd   3

7/1/14   12:23 PM

Summary of Contents for ALT-126R UltraMatch

Page 1: ...ALT 126R Volume Control Installation Manual ALT 126R_Manual indd 1 7 1 14 12 23 PM ...

Page 2: ...ce should be connected to a power supply only of the type described in the operating instructions or as marked on the appliance 9 Grounding or Polarization Precaution should be taken so that the grounding or polarization means of an appliance is not defeated 10 Object and Liquid Entry Care should be taken so that objects do not fall and liquids are not spilled into the enclosure through the openin...

Page 3: ...ing Make sure the amplifier has 20 watts per channel for each pair of speakers to be connected How many ALT 126R An UltraMatch volume control should be used for each pair of speakers however up to 2 pairs of speakers can be used on each control Speaker rating A minimum 4 ohm speaker load can be connected to the Output of each UltraMatch volume control Impedance matching switch Each ALT 126R in the...

Page 4: ... s minimum impedance If the amplifier is 6 ohm stable use the 8 ohm chart Appropriate row and column Cross reference the total number of 4 ohm pairs of speakers rows on charts below with the total number of 8 ohm pairs of speakers columns on charts below to choose the right switch position 1X 2X 4X or 8X see illustration on page 5 0 1 2 3 4 5 6 7 8 0 1X 2X 4X 4X 8X 8X 8X 8X 1 2X 4X 4X 8X 8X 8X 8X ...

Page 5: ...PEDANCE MATCHING Note before accessing impedance switch remove knob and front plate Front plate is attached to the frame with 4 tabs use caution to push the tabs out of the frame Front cover Knob Tab Frame ALT 126R_Manual indd 5 7 1 14 12 23 PM ...

Page 6: ...ming or buzzing sound to be heard through the speakers If it is necessary to locate the volume control near electrical devices install it in a separate metal electrical box ground the box to the electrical system ground and route the speaker wires several feet away from the electrical wiring EZB Connecting Blocks The EZB 8 connecting block a Russound accessories that simplifies the connection of m...

Page 7: ...d the excess wire out the back of the junction box will help you with the final assembly Operation 1 Turn the amplifier receiver OFF and set its volume to minimum 2 Set all the ALT 126R volume controls to maximum fully clockwise 3 Turn on the amp receiver and select a music source e g tuner or CD player 4 Slowly turn up the amplifier receiver volume to the maximum desired listening level and leave...

Page 8: ...8 Russound ALT 126R Installation Manual INSTALLATION EXAMPLE ALT 126R_Manual indd 8 7 1 14 12 23 PM ...

Page 9: ...pedance matching type Autoformer based Quick connect terminals 4 pole screw down accepts up to 12 gauge cable Attenuation 12 steps including Off total attenuation 48 dB Frequency response 20Hz 20kHz 1 0 0 5 dB at rated power Mounting Standard 22 cu in single gang junction box Dimensions 1 625 W x 2 675 H x 2 5 D 41 x 73 x 63 mm Weight 1 lb 453g ALT 126R_Manual indd 9 7 1 14 12 23 PM ...

Page 10: ...orized Dealers and Distributors to ensure that customers obtain proper support and service Any Russound product purchased from an unauthorized dealer or other source including retailers mail order sellers and online sellers will not be honored or serviced under existing Russound warranty policy Any sale of products by an unauthorized source or other manner not authorized by Russound shall void the...

Page 11: ...11 Russound ALT 126R Installation Manual ALT 126R_Manual indd 11 7 1 14 12 23 PM ...

Page 12: ...1389 07 01 14 2014 Russound All rights reserved All trademarks are the property of their respective owners Specifications are subject to change without notice Russound is not responsible for typographical errors or omissions ALT 126R Volume Control Installation Manual ALT 126R_Manual indd 12 7 1 14 12 23 PM ...