Russell Hobbs RHMA 055 Installation Instructions / Warranty Download Page 18

SERVICING  THE  APPLIANCE

 

There are no user serviceable parts in this appliance. If the unit is not operating correctly, 

please check the following: 

  You have followed the instructions correctly

 

  That the unit has been wired correctly and that the wall socket is switched on.

 

  That the mains power supply is ON.

 

  That the plug is firmly in the mains socket. 

 

If the appliance still does not work after checking the above: 

- Consult the retailer for possible repair or replacement. If the retailer fails to resolve the problem 

and you need to return the appliance, make sure that:

 

  The unit is packed carefully back into its original  packaging. 

  Proof of purchase is attached. 

  A reason is provided  for why it is being returned. 

 

If the supply cord is damaged, it must be replaced by the manufacturer or an authorised service 

agent, in order to avoid any hazard. If service becomes necessary within the warranty period, 

the appliance should be returned to an approved  Home of Living  Brands (Pty) Limited service 

centre. Servicing outside the warranty period is still available,  but will, however, be chargeable.

 

 
CHANGING  THE  PLUG 

 

Should  the  need arise to change  the  fitted plug,  follow  the  instructions  below. 

This unit is designed to operate on the stated current only. Connecting to other 
power sources may damage the appliance.  Connect a three-pin plug as follows: 

The  wires in this mains lead are coloured in accordance with  the  following  code: 
 
Green/Yellow 

= Earth 

Blue   

= Neutral 

Brown  

= Live 

 
 
 
 

 
 
 
 

 

 

Summary of Contents for RHMA 055

Page 1: ...INSTRUCTIONS WARRANTY MODEL RHMA 055 MOBILE AIR CONDITIONER...

Page 2: ...sposed of safely to prevent the hazard of electric shock Mains AC Operation This appliance is designed to operate on 220 240V current only Connecting to other pow er sourcesmay damage the unit The w i...

Page 3: ...ectric shock do not immerse or expose assembly plug or the pow er cord to w ateror any other liquid 14 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never...

Page 4: ...ormed byan authorized service representative Failure to do so could resultin a loss ofwarranty A damaged supplycord should be replaced by the manufacturer its service agent or a qualified person in or...

Page 5: ...ose and connection with piece 1 11 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 12 Round cap for filling the hole in wall window 13 Exhaust hose 14 Foam...

Page 6: ...trip into window gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using th...

Page 7: ...up causing the unit to overheat and shut down Fig 8 9 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The lengt...

Page 8: ...2 Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the fi...

Page 9: ...purchased 7 Swing button 8 Sign for sleep function 9 Sleep function button 10 Temperature down button 11 Room temperature display 12 Receiver for remote control 13 Timer display 14 Temperature up but...

Page 10: ...window will show the temperature you set as you press Temperature up or Temperature down button Otherwise it will always show the ambient temperature 3 The pre setting temperature of this machine is...

Page 11: ...e air vent will rise in 3 different angles 45 60 75 Every time when you turn on the machine the air vent will rise to position 75 first then return to position 45 automatically For re setting the angl...

Page 12: ...ssor and motor will stop The water full sign will light up also the machine will beep as a reminder To make the cooling function work again please empty the water tank by one of the following ways 1 T...

Page 13: ...outlet as shown and locate the other end into a drain FIG 17 The drain tube may be extended by adding an extension tube and using a suitable connector FIG 18 Please note 1 The drain must be at or belo...

Page 14: ...ever use aggressive chemicals gasoline detergents chemically treated cloths or other cleansing solutions These all could possibly hurt the cabinet Cleaning the filter Use a vacuum cleaner or tap the f...

Page 15: ...fore completely operating the unit on ventilation only mode for a few hours to thoroughly dry the inside Clean or change the filter Unplug and store the power cord as shown Replace in the original car...

Page 16: ...o many people in the room Is there something in the room producing lots of heat If The machine seems to do nothing Is the filter dusty contaminated Is the air intake or output blocked up Is the room t...

Page 17: ...40V 50Hz Compressor rotary Refrigerant R410A Please refer to the rating label Fan speed 3 Timer 1 24 hours Working temperature Cooling 18 32 o C Heating 7 27 o C Exhaust pipe 142 x 1500mm Net Weight 3...

Page 18: ...roof of purchase is attached A reason is provided for why it is being returned If the supply cord is damaged it must be replaced by the manufacturer or an authorised service agent in order to avoid an...

Page 19: ...exchange the product in terms of this warranty subject to legislative requirements This warranty shall be valid only where the customer has not broken the product himself or used the product for somet...

Reviews: