FAULT CHECK LIST 

 

If The air conditioner does not run 

 

Is the air conditioner plugged in? 

 

Is there a power failure? 

 

Is the comp / ‘full water’ indicator flashing? 

 

Is  the  room  temperature  below  the  set 
temperature?  

 

If The machine seems to do little 

cooling 

 

Is there direct sunshine ? (Please put down 
the curtain.) 

 

Are too many  windows or doors open? 

 

Are there too many people in the room? 

 

Is  there  something  in  the  room  producing 
lots of heat? 

 

If The machine seems to do 

nothing. 

 

Is the filter dusty, contaminated? 

 

Is the air intake or output blocked up? 

 

Is  the  room  temperature  below  your 
selected temperature? 

 

Is Too noisy 

 

Is  the  machine  positioned  unevenly  so  as 
to create vibration ? 

 

Is  the  floor  underneath  the  machine 
uneven? 

 

If 

The compressor doesn’t run. 

 

Is so, it is possible the overheat protection 
of  the  compressor  is  on.  Just  wait  for  the 
temperature to drop. 

 Never try to repair or dismantle the unit yourself 

 

 

 

 

Summary of Contents for RHMA 055

Page 1: ...INSTRUCTIONS WARRANTY MODEL RHMA 055 MOBILE AIR CONDITIONER...

Page 2: ...sposed of safely to prevent the hazard of electric shock Mains AC Operation This appliance is designed to operate on 220 240V current only Connecting to other pow er sourcesmay damage the unit The w i...

Page 3: ...ectric shock do not immerse or expose assembly plug or the pow er cord to w ateror any other liquid 14 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never...

Page 4: ...ormed byan authorized service representative Failure to do so could resultin a loss ofwarranty A damaged supplycord should be replaced by the manufacturer its service agent or a qualified person in or...

Page 5: ...ose and connection with piece 1 11 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 12 Round cap for filling the hole in wall window 13 Exhaust hose 14 Foam...

Page 6: ...trip into window gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using th...

Page 7: ...up causing the unit to overheat and shut down Fig 8 9 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The lengt...

Page 8: ...2 Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the fi...

Page 9: ...purchased 7 Swing button 8 Sign for sleep function 9 Sleep function button 10 Temperature down button 11 Room temperature display 12 Receiver for remote control 13 Timer display 14 Temperature up but...

Page 10: ...window will show the temperature you set as you press Temperature up or Temperature down button Otherwise it will always show the ambient temperature 3 The pre setting temperature of this machine is...

Page 11: ...e air vent will rise in 3 different angles 45 60 75 Every time when you turn on the machine the air vent will rise to position 75 first then return to position 45 automatically For re setting the angl...

Page 12: ...ssor and motor will stop The water full sign will light up also the machine will beep as a reminder To make the cooling function work again please empty the water tank by one of the following ways 1 T...

Page 13: ...outlet as shown and locate the other end into a drain FIG 17 The drain tube may be extended by adding an extension tube and using a suitable connector FIG 18 Please note 1 The drain must be at or belo...

Page 14: ...ever use aggressive chemicals gasoline detergents chemically treated cloths or other cleansing solutions These all could possibly hurt the cabinet Cleaning the filter Use a vacuum cleaner or tap the f...

Page 15: ...fore completely operating the unit on ventilation only mode for a few hours to thoroughly dry the inside Clean or change the filter Unplug and store the power cord as shown Replace in the original car...

Page 16: ...o many people in the room Is there something in the room producing lots of heat If The machine seems to do nothing Is the filter dusty contaminated Is the air intake or output blocked up Is the room t...

Page 17: ...40V 50Hz Compressor rotary Refrigerant R410A Please refer to the rating label Fan speed 3 Timer 1 24 hours Working temperature Cooling 18 32 o C Heating 7 27 o C Exhaust pipe 142 x 1500mm Net Weight 3...

Page 18: ...roof of purchase is attached A reason is provided for why it is being returned If the supply cord is damaged it must be replaced by the manufacturer or an authorised service agent in order to avoid an...

Page 19: ...exchange the product in terms of this warranty subject to legislative requirements This warranty shall be valid only where the customer has not broken the product himself or used the product for somet...

Reviews: