Sleep function 

1. 

In  cooling  mode,  by pressing  the SLEEP button,  the set temperature  will  increase  1

o

C at the 1st 

hour,  another  1

 o

C at the second  hour,  then  keeps at that temperature.   

2. 

In  heat  mode, by pressing  the SLEEP button,  the set temperature  will  descend  1

o

C  at the 1st hour, 

another  1

 o

C at the second  hour,  then  keeps at that temperature.   

3. 

In  sleep mode,  the ventilation  will keep  at low  speed. Re-press  the SLEEP button,  the setting 
temperature  and  ventilation  speed  will  return  to the pre-selected  one. 

4. 

The  unit will shut down  automatically after  the SLEEP function  running  for  12  hours.  

5. 

Please  note,  the sleep  function  is  not  available  while the  machine is  working in ventilation, 
dehumidification  or auto  mode.  Only available  in Cooling or Heating  mode.  

6. 

When the  machine  is in Sleep function,  the  Fan Speed  would turn  to be  LOW speed.  

 

Swing function 

By pressing  SWING  button,  the air  vent  will rise in 3 different  angles:  45º

60º

75º 

Every  time when  you  turn on  the machine,  the air  vent  will rise to position 75º  first, then return  to position 
45º automatically.   For  re-setting  the  angle,  the air vent  will  rise to 75º first, too.   The  interval  of  each 
move  is 4 sec..  As you turn  off  the air  vent,  the air vent  will close.  

  

 

 

 

 

 

FIG.14

 

Dehumidification function 

In  dehumidification  mode,  the temperature  cannot be  adjusted,  the ventilation  will fix at low  speed.  

 

Heating function 

When  using Heat  Pump, it can reverses  the compressor  discharging  the  hot air indoor  instead. 

The 

Exhaust  Pipe must  still  be fitted to  allow the cold air to be removed in this  mode & used  in the 

usual  way

. Under  this system, the machine  can run  at HIGH/MED./LOW  speed.    

                                                             

Self-diagnosis 

This  machine  is equipped  with self-diagnosis  function.   If  something  is wrong  in the  machine, the  LCD  will 
show the word  “E1” or “E2”.  As this time, please call your service   centre.  

 

 
 
                                     
 
 
 
 
 

 

All  the  above  functions  can  also  be  performed  with  the 
supplied  remote  control. 

This  remote  control  requires  2  pcs  AAA  batteries  to 
operate 

 
 
 
 
 

 
FIG.15 

45

o

                        60

 o

                      75

 o

  

Summary of Contents for RHMA 055

Page 1: ...INSTRUCTIONS WARRANTY MODEL RHMA 055 MOBILE AIR CONDITIONER...

Page 2: ...sposed of safely to prevent the hazard of electric shock Mains AC Operation This appliance is designed to operate on 220 240V current only Connecting to other pow er sourcesmay damage the unit The w i...

Page 3: ...ectric shock do not immerse or expose assembly plug or the pow er cord to w ateror any other liquid 14 This heater is not intended for use in bathrooms laundry areas and similar indoor locations Never...

Page 4: ...ormed byan authorized service representative Failure to do so could resultin a loss ofwarranty A damaged supplycord should be replaced by the manufacturer its service agent or a qualified person in or...

Page 5: ...ose and connection with piece 1 11 Outward adaptor for insertion over hose and into foam strip or into hole in the wall window 12 Round cap for filling the hole in wall window 13 Exhaust hose 14 Foam...

Page 6: ...trip into window gaps as shown and slide window across so that foam is held securely This technique may also be used for sash windows Note Take care to maintain protection against intruders 2 Using th...

Page 7: ...up causing the unit to overheat and shut down Fig 8 9 show correct position The hose may be extended from 300mm to 1500mm but for maximum efficiency use the shortest length possible WARNING The lengt...

Page 8: ...2 Separate the filter fixer from the filter frame 3 Remove the active carbon filter from its plastic bag 4 Insert the active carbon filter into the filter frame 5 Fix the filter by reassembling the fi...

Page 9: ...purchased 7 Swing button 8 Sign for sleep function 9 Sleep function button 10 Temperature down button 11 Room temperature display 12 Receiver for remote control 13 Timer display 14 Temperature up but...

Page 10: ...window will show the temperature you set as you press Temperature up or Temperature down button Otherwise it will always show the ambient temperature 3 The pre setting temperature of this machine is...

Page 11: ...e air vent will rise in 3 different angles 45 60 75 Every time when you turn on the machine the air vent will rise to position 75 first then return to position 45 automatically For re setting the angl...

Page 12: ...ssor and motor will stop The water full sign will light up also the machine will beep as a reminder To make the cooling function work again please empty the water tank by one of the following ways 1 T...

Page 13: ...outlet as shown and locate the other end into a drain FIG 17 The drain tube may be extended by adding an extension tube and using a suitable connector FIG 18 Please note 1 The drain must be at or belo...

Page 14: ...ever use aggressive chemicals gasoline detergents chemically treated cloths or other cleansing solutions These all could possibly hurt the cabinet Cleaning the filter Use a vacuum cleaner or tap the f...

Page 15: ...fore completely operating the unit on ventilation only mode for a few hours to thoroughly dry the inside Clean or change the filter Unplug and store the power cord as shown Replace in the original car...

Page 16: ...o many people in the room Is there something in the room producing lots of heat If The machine seems to do nothing Is the filter dusty contaminated Is the air intake or output blocked up Is the room t...

Page 17: ...40V 50Hz Compressor rotary Refrigerant R410A Please refer to the rating label Fan speed 3 Timer 1 24 hours Working temperature Cooling 18 32 o C Heating 7 27 o C Exhaust pipe 142 x 1500mm Net Weight 3...

Page 18: ...roof of purchase is attached A reason is provided for why it is being returned If the supply cord is damaged it must be replaced by the manufacturer or an authorised service agent in order to avoid an...

Page 19: ...exchange the product in terms of this warranty subject to legislative requirements This warranty shall be valid only where the customer has not broken the product himself or used the product for somet...

Reviews: