PTX 

Number 

DMX 

Value 

DMX/VISCA ID DIP POSITION 

PTX 

Number 

DMX 

Value 

DMX/VISCA ID DIP POSITION 

  1 

 

85 

 

15 

 

99 

 

29 

 

113 

 

43 

 

10  127 

 

57 

 

11  141 

 

71 

 

12  155 

 

 

To configure additional PTX heads, select and enter the DMX/VISCA ID for each head. 

Increment each head based on the number of channels in the profile. For 14 channels the 

second fixture would be DMX ID 15, the third 29, etc. as indicated in the graphic. 

 

 

To help you determine appropriate DIP 

settings we’ve included a small file, 

dipcalc.exe, on the USB card included in the 

PTX box. It’s also available on the Ctrl+R 

page on the website. Use the Increment 

function with the profile channel number to 

obtain consecutive DMX addresses. 

 

 

After you’ve entered the Increment value, click 

Next >> to obtain addresses, starting from the 

DMX Address you enter in the field. 

 

SETTING THE MODE DIP SWITCH 

 

 

 

There are currently TWO methods of controlling the PTX Universal PanTilt Heads: DMX 

control from a console or software; and VISCA control, using a number of controllers that 

support VISCA serial control output. 

 

It’s important to understand the distinction between CONTROLLER and CAMERA. The 

Controller is the device that connects to either the DMX IN (XLR), or the green 9-pin Phoenix 

connector that supports two-way RS-422 serial communications with the controller. 

 

The Camera is a camera or camcorder connected to the tilt plate on the PTX fixture. Cameras 

are controlled using the internal protocols supported by the PTX. These include LANC, 

Panasonic Remote and VISCA connections. 

Summary of Contents for PTX Model 1

Page 1: ...LANC 12VDC for Blackmagic Micro Studio 4K 2 RS 422 485 3 RS 232 4 LANC 5 Panasonic Remote two wires 6 BNC BNC cable for use with Mini BNC adapter to take SDI out from a standard BNC on a camera The t...

Page 2: ...he fixture x 20 threaded plate for tripod stand mounting Use the two included 5mm Allen screws to secure the plate to the bottom of the PTX x 20 x thumb screw with washer for attaching camera to tilt...

Page 3: ...cameras have a x 20 thread for mounting on tripods and stands Use the included x 20 x thumbscrew with plastic washer to mount your camera of choice to the tilt plate Shown here is the bottom of the B...

Page 4: ...TO INITIALIZE AND OPERATE PROPERLY ALSO REMOVE THE HAND STRAP ON THE RIGHT SIDE OF THE CAMERA SO IT WILL MOUNT PROPERLY ON THE TILT CRADLE With the PTX powered OFF tilt the plate forward and place the...

Page 5: ...sure with your fingers as possible to assure a solid and secure mount The PTX Model 1 Internal Wiring Bundle To minimize torsional stress on wires and connectors in a housing that can spin 360 the wir...

Page 6: ...ra Then connect the LANC TO CAM and 12VDC TO CAM cables to the two cables connectors from the HD15 DMX Control If you re using more than one PTX head connect the DMX OUT to the DMX IN of each fixture...

Page 7: ...voltage accordingly before you connect the PTX power connector to the camera s DC power input Use the built in voltage display meter to confirm your settings during output adjustment Improper voltage...

Page 8: ...esses starting from the DMX Address you enter in the field SETTING THE MODE DIP SWITCH There are currently TWO methods of controlling the PTX Universal PanTilt Heads DMX control from a console or soft...

Page 9: ...cameras SW3 CAMERA ON for 38400 Baud rate only active if SW 1 and 2 are ON OFF for 9600 Baud rate only active if SW 1 and 2 are ON SW4 CAMERA ON for RS422 or RS285 serial connection if SW1 and SW2 ON...

Page 10: ...ra Control Utility which includes a four port USB to RJ45 MUX that provides serial and 12VDC on CAT5 cables to each camera and or PTX fixture Additionally the VDESK and REMO Integrated PTZ PTX Product...

Page 11: ...to allow connectivity with most camera types 1 RS 422 485 2 RS 232 3 LANC 4 Panasonic Remote two wires Cable bundle clamp and screw if used with Blackmagic Micro Studio 4K camera x 20 x thumb screw wi...

Page 12: ...the Model 2 tilt plate Some cameras like the AJA RovoCam and Marshall CV models have threaded mounts on both the bottom and the top so you can mount them upside down on the tilt plate then mount the...

Page 13: ...mbscrew to secure the camera but only tight enough that the camera can slide forward and backward along the slot Move the tilt plate to the horizontal position and slide the camera forward and back wh...

Page 14: ...nix connector Note If your camera requires a GENLOCK source use the SDI IN on the chassis for that signal and run a short BNC cable from the OUT on the Model 2 arm for connection with the Genlock In o...

Page 15: ...the current Address assignment Click the ENTER button a final time to Save the DMX Address setting Note be sure to set the MODE and DMX VISCA ID DIP switches on the top base of the PTX at the same tim...

Page 16: ...ain consecutive DMX addresses After you ve entered the Increment value click Next to obtain addresses starting from the DMX Address you enter in the field SETTING THE MODE DIP SWITCH There are current...

Page 17: ...are SW2 CAMERA ON for VISCA only active if SW1 is ON OFF for LANC and Panasonic Remote controlled cameras SW3 CAMERA ON for 38400 Baud rate only active if SW 1 and 2 are ON OFF for 9600 Baud rate only...

Page 18: ...ra Control Utility which includes a four port USB to RJ45 MUX that provides serial and 12VDC on CAT5 cables to each camera and or PTX fixture Additionally the VDESK and REMO Integrated PTZ PTX Product...