Ingress protection rating ........................................................................... IP 20
Installation
Mounting points ............................. One quarter
‐
turn bracket for rigging clamp
Location .................. Indoor use only, must be fastened to surface or structure
Orientation .................................................................................................. Any
Minimum distance to illuminated surfaces ................................ 200 mm (8 in.)
Minimum distance to combustible materials ............................. 100 mm (4 in.)
Minimum clearance around fans and vents .............................. 100 mm (4 in.)
Connections
AC power input .................................................................... Neutrik PowerCon
AC power throughput .......................................................... Neutrik PowerCon
DMX data in/out ........................................................ 3-pin & 5-pin locking XLR
Electrical
AC power ............................................................ 100-240 V nominal, 50/60 Hz
Power supply unit ................................... Auto-ranging electronic switch mode
Fuse ..................................................................................................... T 3.15 A
Recommended Miniature Circuit Breaker* ............................................ Type D
*Per IEC 60898/UL489/CSA C22.2 No. 5
Typical power and current
120 V, 60 Hz .................................................................. 1.3 A, 155 W, PF 0.99
230 V, 50 Hz .................................................................. 0.7 A, 155 W, PF 0.94
Typical half-cycle RMS inrush current at 240 VAC ................................ 11.3 A
Measurements made at nominal voltage with all LEDs at full intensity. Allow
for a deviation of +/- 10%.
Thermal
Cooling ..................................... Forced air (temperature regulated, low noise)
Maximum ambient temperature (T
a
max.) ................................ 40° C (104° F)
Minimum ambient temperature (T
a
min) ........................................ 0° C (32° F)
Approvals
EU safety .. EN 60598
‐
2
‐
17, EN 62031, EN 62793, EN 62471
‐
1/ EN 62471
‐
2,
....................... EN 61347-2-13: 2014 (EN 61347-1:2008 +A1:2011 +A2:2012)
EU EMC ........................... EN 55015, EN 55032, EN 55103-2, EN 61000-3-2,
........ EN 61000-3-3, EN 61000-4-2, EN 61000-4-4, EN 61000-4-5, EN 61547
US safety ............................................................................. UL 1573, UL 8750
US EMC ........................................................................................ FCC Part 15
Canadian safety ................................................................ CSA C22.2 No. 166
Australia/NZ ............................................................................... C-TICK N4241