14
Installation and setting up
Before connecting the system to power, verify that the AC supply is adequately
dimensioned for the current draw of the system.
Base unit
0.9 A @ 230 V (EU model)
1.7 A@ 120 V (US model)
Fog Heads
5.1 A @ 230 V (EU model)
8.6 A @ 120 V (US model)
Haze Heads
4.0 A @ 230 V (EU model)
7.6 A @ 120 V (US model)
Check that the local AC voltage is appropriate, as indicated on the system’s
serial number label. If your AC voltage is outside the appropriate range, do not
use the system. Contact Martin Service for assistance.
Setting up
Fill the fluid tank only with Martin RUSH Club Smoke Dual Fluid™ (see page 25).
Up to two heads of the same type (fog or haze) may be connected to each fluid
output of the pump unit. Push the fluid tubing into the connections on the head
and the pump unit and secure on the heads using the locking screw. If two
heads are being connected to an output, a T-connector must be fitted in the fluid
tubing.
It is recommended that if you are using Haze heads you should
connect them to channel 1
Connect the RJ45 control connection on the heads to the pump unit. If two
heads are being connected to a channel, use the RJ45 link output on the first
head to connect the second head. The RJ45 connectors are linked together
internally and either can be used as input or link.
Connection of single head