THE HYDROPHORE
SWITCHES OFF AFTER
A SHORT PERIOD OF
OPERATION BECAUSE
ONE OF THE HEAT
PROTECTION
SWITCHES HAS
TRIGGERED
1. Power supply
electrical is not in
accordance with the data
on the stamp plate
2. A solid object locks the
rotors.
3. The liquid is too
dense.
4. The liquid or
environment is too hot.
5. The hydrophore
operates without fluid,
the check valve on the
suction circuit is closed.
1.Verificatenandunota de la
terminaitethem cabituitui de
alimentare.
2. Dezasambitaand
curatayouhydrophore.
3. Diluayou fituiduit
pampat.
4-5. EitimiN / Ati chaveza
probitemei , aSteptayou that
hydrophore to se racshescale
andsa reporneasca.
THE HYDROPHOR
STARTS AND STOPS
TOO FREQUENTLY
1. The tank diaphragm is
damaged.
1. Have qualified diaphragm or
tank replaced by qualified
personnel.
THE HYDROPHORE
DOES NOT REACH
THE DESIRED
PRESSURE
1. The pressure required
to turn off the preset
hydrophore on the
pressure switch is too
low.
2. Air intake from the
suction pipe.
1. Contact the service.
2. See point 2.2.
THE HYDROPHORE
DOES NOT WORK
CONTINUOUSLY
1. The pressure required
to turn off the preset
hydrophore on the
pressure is too low.
2. Air intake from the
suction pipe.
1. Contact the service.
2. See point 2.2.
Summary of Contents for AquaPower 1008S
Page 1: ...Hidrofor RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Page 39: ...HU RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S Hidrofor ...
Page 77: ...EN Hydrophore RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Page 91: ...BG Хидрофор RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Page 107: ...PL RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...
Page 120: ...SRB HRV BIH Hidrofor RURIS AquaPower 1008S 2010S 2011S 3009S 4010S 5010S 6009S 8009S ...