R&D department
2018/08/01
1.1.28
setcfg
This SMS message is dedicated to change FM parameters. After SMS password, user inputs parameter ID and
parameter value:
password
setcfg
ParamID1 Value1, ParamID2 Value2, ParamID3 Value3, …
Examples:
password setcfg 101 wave, 102 pioneer, 103 , 100 1
Sets APN name: wave, APN user: pioneer, no APN password, Protocol: UDP
password setcfg 4362 6, 4202 1, 4242 12, 4282 5, 4322 10
Sets IO in 4 profile, slot 3. IO modem temperature: enabled, level is 12, delta is 5, average is 10, event on – hysteresis on
both
Only parameters provided with SMS are changed, others remain the same.
One SMS message can be 160 symbols long, so the maximum simultaneously transmitted parameters count in
SMS message are limited to one message length.
Setcfg command, allows user to change all parameters of the configuration except timetable (because it will not
fit into one SMS message), passwords (configuration and SMS) and “enable SMS configuration”.
Following responses are provided for the number, which sent configuration by SMS:
•
When successfully setting parameters for FM device: „Configuration parameter(s) was set!“
•
Incorrect parameter setting: „
Configuration parameter(s) was NOT set! Parameter No. 1 is incorrect
“.
•
Unsuccessful set-up, when parameters are locked: „
Configuration parameter(s) was NOT set! Parameter No. 1 is
locked
“
•
Unsuccessful set-up, when setting IO parameters, but not every setting was provided by SMS: „
Configuration
parameter(s) was NOT set! IO slot No. 9 is not fully set
“.
•
Unsuccessful set-up, when device is busy: „
Configuration parameter(s) was NOT set! Device is busy try again
later
“
•
If SMS configuration is disabled in configuration tool: „
You do not have permission to change the settings
“.
SMS configuration feature is enabled/disabled in configuration tool, in Authorized numbers section, by putting a
checkbox by the „Enable SMS configuration“.
1.1.29
getcfg
Structure of getcfg SMS:
password
getcfg
id
20