R&D department
2018/08/01
If configuration SMS is incorrect, device will response: s
etiotime syntax error in DOUTX settings: error text
Where „DOUTX“ is DOUT1 or DOUT2. „Error text“ is described below in the table. It's minimal diagnostic when
something wrong with impulse set in SMS.
Error text
Error description
other process controls output
Means that other functionality is configured on DOUT's. For example: LED or
buzzer
no comma symbol
No comma separator. Comma is used to separate DOUT's configuration
wrong format
When was received not enough symbols
wrong level
Level can be only logical '1' or '0'. Other values is unacceptable
no space symbol
After level symbols must to be space symbol
wrong ms number
Wrong time number
wrong repeat number
Wrong repeat count number
exceeded max slot
For one output is possible to set maximum 10 slot. If this count is exceeded this
error is displayed
pulse is shorter than 10ms
Pulse length less than 10 milliseconds was set. It's not acceptable
other reason
Includes other reason not described in this table
1.1.23
Banned – temporary banned operators
SMS message is used with 4gen FM device. Purpose is to get information about temporary banned operators.
Answer SMS format:
Already banned:X, Newly banned:Y, ops:ZZZ.
Parameter
Description
X
Number of times when FM tried to ban operator which has
already been in the banned list.
Y
Number of times when FM added operator in the banned list.
ZZZ
List of currently banned operators (which are still in the list).
Example:
pass
banned
Response example:
Already:1, Newly banned:1, ops:24602,
17