Troubleshooting 

Problem 

Possible Cause 

Solution 

Filter Fails to 
Backwash 

a.

 

Power to controller has 
been interrupted 

b.

 

Backwash cycle times set 
incorrectly 

c.

 

Controller Damaged 

a.

 

Check power 
connection is ok 

b.

 

Reset the backwash 
cycle times 

c.

 

Check or replace 
controller 

 

Filter passing 
raw water 

a.

 

Bypass valve is open 

b.

 

Damaged riser pipe 

c.

 

Internal Valve Leak 

a.

 

Close Bypass Valve 

b.

 

Check the riser pipe is 
not cracked and O-
ring is ok 

c.

 

Check or change valve 
body 

Water 
pressure loss 

a.

 

Filter requires a backwash  

b.

 

Check no blockage in 
pipework 

a.

 

Backwash filter 

b.

 

Unblock pipework 

Loss of media 
material 
through drain 
line 

a.

 

Air in the system 

b.

 

Backwash flow control to 
high 

c.

 

Top screen broken 

a.

 

Bleed air from the 
system. Check for 
leaks 

b.

 

Reduce Backwash 
flow to suitable size 

c.

 

Check and replace top 
screen 

Control valve 
cycle 
continuously 

a.

 

Wrong size transformer 

b.

 

Foreign material stuck in 
drive gear 

c.

 

Faulty valve 

a.

 

Use correct 
Transformer 

b.

 

Remove Foreign 
material from drive 
gear 

c.

 

Replace valve 

Water flowing 
through drain 
line continually 

a.

 

Power outage during 
backwash or fast rinse 

b.

 

Internal Valve leak 

a.

 

Turn on Power, cycle 
through to service  

b.

 

Check or replace 
valve body 

All indicators 
display on the 
controller 

a.

 

Wiring between the 
display board and control 
board failure 

b.

 

Control board is faulty 

a.

 

Check a replace cable 

b.

 

Replace control board 

c.

 

Check or replace 
transformer 

Summary of Contents for 41-S150

Page 1: ...Page 1 of 12 CABINET WATER SOFTENER RUNXIN VALVE PROGRAMMING PROCEDURE Models Cabinet Softener RL R150 F69P3 F70BL 74602 ...

Page 2: ...Page 2 of 12 Valve Buttons Valve Configuration ...

Page 3: ...outlet 3 4 F Drain 1 2 M Brine line connector 3 8 M Base 2 5 8NPSM Riser pipe 1 05 OD Resin Amount 28Lts Water treatment capacity 2 m h Tank diameter 10 x 35 Water pressure 0 15MPa 0 6MPa Water temperature 5 38 Water turbidity Up flow regeneration 2FTU Power adapter Input AC100 240V 50 60Hz Output DC12V 1 5A ...

Page 4: ...Page 4 of 12 Button Operation Menu Confirm Start Regeneration Skip Regeneration Cycle Return Down Up Valve Locked Press Simultaneously for 5 secs to unlock the screen ...

Page 5: ...Page 5 of 12 Control Valve Symbols Backwash Brine Draw Brine Refill Fast Rinse Settings Clock Days until Backwash Controller Locked ...

Page 6: ...r with constant power out the GPO Water pressure not to exceed 600kPa with a minimum pressure required of 0 15kPa Easily accessible for maintenance of the unit Add salt to the brine tank Installation Connect the inlet and outlet pipework as per the directional arrows on the back of the water softener valve Female BSP connections Run the drain line to an open drain line an air gap is required to pr...

Page 7: ...or 5 secs until you hear a beep Press the Menu Button Press the Down arrow Press Menu The hour will then flash change the Hour time to desired time by pressing the up or Down button press Menu to save The minutes will then flash Change the minutes time with the up or down arrow and press menu to confirm changes Regenerate on 0m Capacity or at Regeneration Set Time Unlock Valve Press Up Down arrow ...

Page 8: ... of days by pressing the up or Down button press Menu to save Set Water softener Capacity Unlock Valve Press Up Down arrow together for 5 secs until you hear a beep Press the Menu Button Press down arrow four An hourglass and a m symbol will light up Press Menu Button The digits will then flash change the number to the amount of capacity estimated for the ion exchange process in litres the softene...

Page 9: ...et Press down The Hourglass and the Brine Draw symbol will light up press menu the time will flash press the up and down arrows to change to 49mins Press menu to confirm Brine Refill Once Brine Draw is set Press down The Hourglass and the Brine Refill symbol will light up press menu the time will flash press the up and down arrows to change to 7mins Press menu to confirm Fast Rinse Once Brine Refi...

Page 10: ... down Slowly open the inlet water connection a turn to allow a small flow of water into the softener to releasing air out of the cylinder Once all the air has been removed from the cylinder you can now open the inlet valve fully to clean the resin bed When the water is running clear press the regen button again to skip to the next cycle The valve will now be in Brine draw cycle press the regen but...

Page 11: ... media material through drain line a Air in the system b Backwash flow control to high c Top screen broken a Bleed air from the system Check for leaks b Reduce Backwash flow to suitable size c Check and replace top screen Control valve cycle continuously a Wrong size transformer b Foreign material stuck in drive gear c Faulty valve a Use correct Transformer b Remove Foreign material from drive gea...

Page 12: ...rd and display board failure b Locating board damaged c Mechanical driver fails d Faulty control board e Wiring between the control board and motor fault f Motor damaged a Replace the wiring between display board and locating board b Replace locating board c Check and repair mechanical part d Replace control board e Replace wiring between control board and motor f Replace motor E2 Flash a Componen...

Reviews: