Page
6
of
12
Water softener Installation
Softener Location
It is important to Install the softener in a suitable place:
•
Preferably indoors. (if outdoors it is recommended to have the unit
undercover or in a shed)
•
As close as possible for water connections, drain line not to be too far
from the unit
•
On a level ground or platform
•
Ambient temperatures to not exceed 49°C or below 1°C
•
Near electrical supply for transformer with constant power out the GPO
•
Water pressure not to exceed 600kPa with a minimum pressure required
of 0.15kPa
•
Easily accessible for maintenance of the unit, Add salt to the brine tank
Installation
•
Connect the inlet and outlet pipework as per the directional arrows on
the back of the water softener valve ¾” Female BSP conn
ections
•
Run the drain line to an open drain line, an air gap is required to prevent
back pressure or a siphon (As per Diagram)
•
Secure all pipework from the water softener
•
Fit a 12mm drain line for the overflow from the side of cabinet softener
to a drain. Air gap required from hose into the drain